Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Table 83: Life Cycle Impact, Base Case, Category F (per 1000 functional lumen)<br />

8<br />

9<br />

TOTAL (per 1000 functional lm)<br />

Other Resources & Waste<br />

166<br />

WEIGHTED<br />

AVERAGE<br />

LPS HPS<br />

Total Energy (GER) MJ 37.024 32.347 37.166<br />

of which, electricity (in primary MJ) MJ 36.840 31.997 36.987<br />

10 Water (process) ltr 2.469 2.169 2.478<br />

11 Water (cooling) ltr 98.209 85.241 98.603<br />

12 Waste, non-haz./ landfill g 45.789 42.210 45.897<br />

13 Waste, hazardous/ incinerated g 1.050 1.049 1.050<br />

Emissions (Air)<br />

14 Greenhouse Gases in GWP100 kg CO2 eq. 1.621 1.422 1.627<br />

15 Ozone Depletion, emissions mg R-11 eq. negligible negligible negligible<br />

16 Acidification, emissions g SO2 eq. 9.556 8.358 9.592<br />

17 Volatile Organic Compounds (VOC) g 14 13 14<br />

18 Persistent Organic Pollutants (POP) ng i-Teq 255 231 256<br />

19 Heavy Metals to Air mg Ni eq. 723 586 727<br />

PAHs mg Ni eq. 105 114 104<br />

20 Particulate Matter (PM, dust) g 237 240 237<br />

Emissions (Water)<br />

21 Heavy Metals to Water mg Hg/20 261 245 262<br />

22 Eutrophication g PO4 2 2 2<br />

23 Persistent Organic Pollutants (POP) ng i-Teq negligible negligible negligible<br />

When comparing the Base Case LPS and HPS luminaires from a total life cycle perspective,<br />

impacts per functional lumen output are in the same order of magnitude, with slight apparent<br />

advantage for LPS (exept for impacts PAHs and PM).