naval dockyard, mumbai - Irfc-nausena.nic.in
naval dockyard, mumbai - Irfc-nausena.nic.in
naval dockyard, mumbai - Irfc-nausena.nic.in
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Activity Description<br />
Remove the coupl<strong>in</strong>g, clean and repair as <strong>in</strong>structed<br />
by the QC(E) rep<br />
Legend<br />
(a) ‘P’ Perform, ‘R’ Review, ‘W’ Witness, ‘H’ Customer/QC Hold Po<strong>in</strong>t,<br />
(b) 1 – Contractor/ Firm, 2 IRS/LRS, 3 – MQCE, 4 – Ship Staff, 5 – Contract Execut<strong>in</strong>g Authority<br />
Notes:<br />
(a)<br />
HCustomer/QC Hold Po<strong>in</strong>t. The contractor is not to proceed further till approval of<br />
QC representative.<br />
(b)<br />
In case of any renewal of material is to be undertaken and the composition is not<br />
known from OEM manuals/ draw<strong>in</strong>gs, the contractor has to undertake the tests of materials from<br />
government approved/NABL accredited laboratory for its composition <strong>in</strong> order to select the<br />
DEPT: QC(E) C. No<br />
74<br />
SHIP: FC MADHUR<br />
NAVAL DOCKYARD, MUMBAI<br />
QUALITY ASSURANCE PLAN<br />
REV DATE: 23 May 12 FORM Q C E 0 7 4 R E 0 1 0<br />
No:01<br />
NO<br />
JOB TITLE :REFIT<br />
QAP No : QCE74 245 QAP DATE : 11JUL12 PAGE 22 OF22<br />
same or equivalent material. The test sample will be stamped by the QC rep. The certificates of the<br />
orig<strong>in</strong>al material and the renewed material is required to be submitted by the firm.<br />
(c)<br />
All the old material (eg: spare parts, sub assemblies etc) are to be handed over to<br />
the ship’s staff / customer and certificate for the same to be submitted to the QC dept prior<br />
completion of refit.<br />
(d)<br />
In case of imported materials, certificates from classification societies are required to<br />
be forwarded.<br />
(e)<br />
Test Certificates. The contractor has to submit relevant test certificates for materials<br />
from Government approved/NABL accredited laboratory.<br />
Environmental and Safety Standards :The firm shall follow all safety norms and IMS (Integrated<br />
Management Systems) standards of ND (MB) <strong>in</strong> accordance with ISO9001:2008 ,ISO14001:2004<br />
& OHSAS 18001:2007.<br />
DYT/INCOD/1213/106(a)/PLYCM/MADHURREFIT/420 105/127