25<br />
Fairleads,Ventilation<br />
trunk<strong>in</strong>g etc<br />
Fitt<strong>in</strong>gs which are<br />
renewed/repaired is<br />
chipped for application of<br />
appro pa<strong>in</strong>t scheme<br />
As per SOW 2 3 3<br />
Pa<strong>in</strong>t scheme<br />
application should<br />
follow crafts record<br />
NAVAL DOCKYARD MUMBAI<br />
DOC CODE Q C H 7 4 Q A P 0 3 8<br />
DEPT : MQC ( HULL) C NO 74 ISSUE<br />
NO 02<br />
DATE : 22 APR 09 PAGE 6 OF 9<br />
26<br />
27<br />
28<br />
29<br />
Overhaul<strong>in</strong>g and eas<strong>in</strong>g<br />
of various units,<br />
mach<strong>in</strong>eries &<br />
equipments<br />
TANK TESTING<br />
Survey and Repair/<br />
Renewal, pressure<br />
test<strong>in</strong>g and chipp<strong>in</strong>g/<br />
clean<strong>in</strong>g and pa<strong>in</strong>t<strong>in</strong>g of<br />
Ballast tanks, Fuel tanks,<br />
F/W gravity tanks and<br />
chipp<strong>in</strong>g/ clean<strong>in</strong>g and<br />
pa<strong>in</strong>t<strong>in</strong>g of E/R and ASP<br />
bilges<br />
CITADEL DEFECTS<br />
Repair/ Renewal of WT<br />
doors, hatches, port holes<br />
and replacement of clips,<br />
nuts etc<br />
Replacement of rubber as<br />
per exist<strong>in</strong>g<br />
As per SOW and<br />
Ships manual for<br />
concerned<br />
equipment<br />
As per SOW<br />
Air pressure<br />
test<strong>in</strong>g of the<br />
tanks at 0.2 bar<br />
pressure for 15<br />
m<strong>in</strong>utes<br />
Pa<strong>in</strong>t<strong>in</strong>g as per<br />
approved pa<strong>in</strong>t<br />
scheme<br />
2 3 3<br />
2 3 3<br />
As per SOW 2 3 3<br />
As per SOW 2 3 3<br />
Firm to submit<br />
separate QAP for<br />
overhaul<strong>in</strong>g of<br />
mach<strong>in</strong>eries<br />
All underwater tanks<br />
(F W tank) to be<br />
blasted to SA 2.5 std<br />
Items which are<br />
manufactured should<br />
as per sample<br />
Only IRMRA procured<br />
rubber to be used and<br />
certificate of same is<br />
submitted to QC<br />
DYT/INCOD/1213/106(a)/PLYCM/MADHURREFIT/420 61/127