(e) Renew defective <strong>in</strong>ternal wir<strong>in</strong>g (as per sample)<br />
(f) Indication lamps to be replaced (as per sample)<br />
L30003 (a) 02 <strong>in</strong> nos GS pump motors 5 HP (415V,3Ph, 50<br />
Hz)to be overhauled.<br />
(b) Both Motors bear<strong>in</strong>gs to be renewed<br />
L30004 (a) Steer<strong>in</strong>g Gear motor 5 HP (415V,3Ph, 50Hz) to<br />
be overhauled.<br />
(b) Both bear<strong>in</strong>gs to be renewed<br />
L30005 (a) Air Compressor motors 5 HP (415V,3Ph, 50Hz)<br />
to be overhauled.<br />
(b) Both bear<strong>in</strong>gs of 02 motors to be renewed<br />
L30006 (a) E/R Supply blower motors 3 HP (415V,3Ph,<br />
50Hz) to be overhauled.<br />
(b) Both bear<strong>in</strong>gs to be renewed<br />
L30007 (a) GS Pump motor stardeltastarters panel<br />
(415V,3Ph, 50Hz)to be overhauled and tested<br />
onboard.<br />
(b) Both OLR(Makesiemens,06 A) to be replaced<br />
(c)Contactors to be replaced (MakeL&T Co. Type<br />
MV1,10/16 amps).<br />
L30008 (a) Steer<strong>in</strong>g Gear motor DOL starter panel (415V,<br />
3Ph , 50Hz) to be overhauled and tested onboard.<br />
(b) OLR(Makesiemens & 06 amps) to be<br />
replaced.<br />
(c) Contactor to be replaced (MakeMar<strong>in</strong>e<br />
electrical Co,10amps)<br />
(d) Steer<strong>in</strong>g Control Panel <strong>in</strong> Wheel House to be<br />
25 mtr<br />
15 nos.<br />
02 nos.<br />
04 nos.<br />
01 nos.<br />
02 nos.<br />
01 nos.<br />
02 nos.<br />
02 nos.<br />
04 nos.<br />
02 nos.<br />
02 nos.<br />
02 nos.<br />
01nos.<br />
01 nos.<br />
02 nos.<br />
01 nos.<br />