of Intercom System &<br />
Loud hailer/ Broad<br />
cast<strong>in</strong>g/ PI /SRE<br />
System/PA system &<br />
VHF/Telecommu<strong>nic</strong>ation<br />
system. / Television<br />
19 Overhaul<strong>in</strong>g,<br />
refurbishment, new<br />
<strong>in</strong>stallation and<br />
commission<strong>in</strong>g / test<strong>in</strong>g<br />
of W<strong>in</strong>dow wiper<br />
system /motor,<br />
20 Overhaul<strong>in</strong>g,<br />
refurbishment,<br />
renewal ,new <strong>in</strong>stallation<br />
and commission<strong>in</strong>g /<br />
test<strong>in</strong>g of Ma<strong>in</strong> steer<strong>in</strong>g<br />
system & Dash board<br />
panel at Wheel<br />
house/bridge /<br />
Steer<strong>in</strong>g gear system<br />
renewed as per sample / OEM make/ reputed make. iv)<br />
Check for fitment, connection, secure & tightness. New<br />
material bill to be submitted v) If item /equipment found<br />
beyond repair to be renewed as per sample/make/ OEM<br />
make/rat<strong>in</strong>g. vi) New material compartment to be offered<br />
the QC check prior to fitment. vii) Check for Operational<br />
performance of Commu<strong>nic</strong>ation system & full load trials<br />
on board. Viii) Check for system operation as per SOW<br />
& Tech manual ix) Check for fitment & operational test<br />
Test certificate to be provided if any<br />
Refer to QAP : QCL074QAP001 for AC/DC Motor<br />
As per Sl No 03<br />
Refer to QAP : QCL074QAP059 for control panels<br />
i) Visual checks for any defects for serviceability.<br />
ii) Check for overhaul<strong>in</strong>g, repair<strong>in</strong>g and clean<strong>in</strong>g /<br />
renewal. iii) Check defective /miss<strong>in</strong>g competent to be<br />
renewed as per sample / OEM make/ reputed make. iv)<br />
Check for fitment, connection, secure & tightness. New<br />
material bill to be submitted v) If item /equipment found<br />
beyond repair to be renewed as per sample/make/ OEM<br />
make/rat<strong>in</strong>g. vi) New material compartment to be offered<br />
the QC check prior to fitment. vii) Measur<strong>in</strong>g <strong>in</strong>struments<br />
1 2&3 3 3<br />
1 2&3 3 3<br />
NAVAL DOCKYARD, MUMBAI<br />
TITLE : QUALITY ASSURANCE PLAN DOC CODE Q C L 7 4 Q A P 0 6 3<br />
DEPT. :<br />
QC(ELECTRICAL )<br />
C. NO. 74 ISSUE NO : 00 DATE : 15 Apr 12 PAGE 10 OF 14<br />
Sr.<br />
No.<br />
ACTIVITY<br />
REFERENCE DOCMENT & CHECK LIST INSPECTION<br />
DESCRIPTION<br />
SCOPE OF WORK P R W H<br />
to be calibrated viii) Check for Operational performance of<br />
Steer<strong>in</strong>g System & full load trials on board. ixi) Check for<br />
system operation as per SOW & Tech manual ix) Check<br />
for fitment & operational test x) Test certificate to be<br />
provided if any<br />
Refer to QAP : QCL074QAP059 for control panels<br />
i) Visual checks for any defects for serviceability.<br />
ii) Check for overhaul<strong>in</strong>g, repair<strong>in</strong>g and clean<strong>in</strong>g / renewal.<br />
iii) Check defective /miss<strong>in</strong>g competent to be renewed as<br />
per sample / OEM make/ reputed make. iv) Check for<br />
21 Overhaul<strong>in</strong>g,<br />
refurbishment,<br />
renewal ,new<br />
<strong>in</strong>stallation and<br />
DYT/INCOD/1213/106(a)/PLYCM/MADHURREFIT/420 76/127