overhauled and tested onboard,<br />
(e) Contactor of control panel (wheel House) to be<br />
replaced.<br />
(f) Indication lamps with holders to be replaced.<br />
L30009 (a) Air Compressor motor stardeltastarters panel<br />
(415V,3Ph, 50Hz)to be overhauled and tested<br />
onboard.<br />
(b) Both OLR(Makesiemens&06amps) to be<br />
replaced.<br />
(c) Contactors to be replaced( MakeMar<strong>in</strong>e<br />
electrical Co, 10/16 amps).<br />
L30010 (a) E/R supply blower motor DOL starters panel<br />
(415V, 3Ph , 50Hz) to be overhauled and tested<br />
onboard.<br />
(b) Both OLR(MakeMar<strong>in</strong>e electricalsCo.&06amps<br />
) to be replaced.<br />
(c) Contactors to be replaced(10/16 amps).<br />
L30011 (a) Crew Acco. Supply blower motor DOL starters<br />
panel (415V, 3Ph , 50Hz) to be overhauled and<br />
tested onboard.<br />
(b) OLR(MakeMar<strong>in</strong>e electricalsCo.&06amps) to<br />
be replaced.<br />
(c) Contactor to be replaced(10/16 amps).<br />
L30012 (a)1 KW Battery charger rectifier 415V, 3Ph,<br />
50hz,to be repaired, tested on board. (Make<br />
Automatic electrical Co.)<br />
(b) One Lead coated, metal box to be<br />
manufactured for battery storage as per sample.<br />
01 nos.<br />