DEPT: QC(E) C. No<br />
74<br />
SHIP: FC MADHUR<br />
REV<br />
No:0<br />
1<br />
NAVAL DOCKYARD, MUMBAI<br />
QUALITY ASSURANCE PLAN<br />
DATE: 23 May 12 FORM Q C E 0 7 4 R E 0 1 0<br />
NO<br />
JOB TITLE :REFIT<br />
QAP No : QCE74 245 QAP DATE : 11JUL12 PAGE 12 OF22<br />
E20024 19. Activity Description<br />
Remove old valves, replace those with new ones as<br />
per given specification and pressure test them <strong>in</strong><br />
the presence of QC (E) Inspector.<br />
1 3 3<br />
Defect Description<br />
The follow<strong>in</strong>g steer<strong>in</strong>g hydraulic system LP/HP<br />
connection (with flexible pipe/hose) to be renewed<br />
as per sample.<br />
(a) HP connection to maneuver<strong>in</strong>g ( size 28 mm<br />
work<strong>in</strong>g pressure 40 kg/cm 2 ) Qty 02<br />
(b) HP connection to Hand pump ( size 28 mm<br />
work<strong>in</strong>g pressure 40 kg/cm 2 ) Qty 02<br />
(c) LP flexible Hose ( size 15 mm work<strong>in</strong>g<br />
pressure 10 kg/cm 2 ) Qty 01<br />
E20025 Activity Description<br />
Remove above mentioned old hoses, replace them<br />
with new ones as per sample, carry out the<br />
hydraulic pressure test<strong>in</strong>g at test pressure at (a)60<br />
kg/cm 2 (b) 60 kg/cm 2 (c) 15 kg/cm 2 respectively and<br />
offer to QC (E) <strong>in</strong>spection.<br />
1 3 3<br />
Defect Description<br />
Air operated pneumatic horn/siren to be renewed<br />
along with stra<strong>in</strong>er, horn valve, isolat<strong>in</strong>g cock and<br />
limit<strong>in</strong>g valve, and to be proven. (MakeM/s<br />
West<strong>in</strong>ghouse Saxby Farmer). Qty 01 set<br />
DYT/INCOD/1213/106(a)/PLYCM/MADHURREFIT/420 95/127