of Wall mounted fan<br />

16 Overhaul<strong>in</strong>g,<br />

refurbishment, new<br />

<strong>in</strong>stallation and<br />

commission<strong>in</strong>g /<br />

test<strong>in</strong>g of Lead Acid<br />

batteries / Dry Cell<br />

batteries /No<br />

ma<strong>in</strong>tenance batteries<br />

17 Renewal /new<br />

<strong>in</strong>stallation and /<br />

test<strong>in</strong>g of Socket /<br />

Switches / Extension<br />

board /Indication<br />

lamps type<br />

per sample / OEM make/ reputed make. iv) Check for<br />

fitment, connection, secure & tightness. New material bill<br />

to be submitted v) If item /equipment found beyond<br />

repair to be renewed as per sample/make/ OEM<br />

make/rat<strong>in</strong>g. vi) New material compartment to be offered<br />

the QC check prior to fitment. vii) Check for Operational<br />

performance & full load trials on board. Vii) Check for<br />

new wall mounted fan Make/sweep/rat<strong>in</strong>g etc. as per<br />

SOW ii) Check for fitment & operational test.<br />

i) Visual checks for any defects for serviceability.<br />

ii) Check for overhaul<strong>in</strong>g, repair<strong>in</strong>g and clean<strong>in</strong>g / renewal.<br />

iii) To be renewed as per sample / OEM make/ reputed<br />

make. iv) Check for fitment, connection, secure &<br />

tightness. New material bill to be submitted vi) Batteries<br />

to be offered the QC check prior to fitment. vii) Check for<br />

Operational and commission<strong>in</strong>g of batteries viii) Batteries<br />

to be tested two times for charg<strong>in</strong>g & discharg<strong>in</strong>g on full<br />

load. Acid density to be checked.<br />

Refer to QAP : QCL074QAP059<br />

i) Visual checks for any defects for serviceability.<br />

ii) Check for clean<strong>in</strong>g / renewal. iv) Check for fitment,<br />

connection, secure & tightness. New material bill to be<br />

submitted v) If item /equipment found beyond repair to<br />

be renewed as per sample/make/ OEM make/rat<strong>in</strong>g. vi)<br />

1 2&3 3 3<br />

1 2&3 3 3<br />

NAVAL DOCKYARD, MUMBAI<br />

TITLE : QUALITY ASSURANCE PLAN DOC CODE Q C L 7 4 Q A P 0 6 3<br />

DEPT. :<br />

QC(ELECTRICAL )<br />

C. NO. 74 ISSUE NO : 00 DATE : 15 Apr 12 PAGE 09 OF 14<br />

Sr. ACTIVITY<br />

No. DESCRIPTION<br />

REFERENCE DOCMENT & CHECK LIST INSPECTION<br />

SCOPE OF WORK P R W H<br />

New material compartment to be offered the QC<br />

check prior to fitment. vii) Check for Operational<br />

performance & full load trials on board. Vii) Check<br />

for new multip<strong>in</strong> switch socket make/ capacity ii)<br />

Check for test as per SOW<br />

18 Overhaul<strong>in</strong>g,<br />

Refer to QAP : QCL074QAP059<br />

1 2&3 3 3<br />

refurbishment, new i) Visual checks for any defects for serviceability.<br />

<strong>in</strong>stallation and ii) Check for overhaul<strong>in</strong>g, repair<strong>in</strong>g and clean<strong>in</strong>g /<br />

commission<strong>in</strong>g / test<strong>in</strong>g renewal. iii) Check defective /miss<strong>in</strong>g competent to be<br />

DYT/INCOD/12­13/106(a)/PL­YCM/MADHUR­REFIT/420 75/127