NAVAL DOCKYARD MUMBAI<br />

DOC CODE Q C H 7 4 Q A P 0 3 8<br />

DEPT : MQC ( HULL) C NO 74 ISSUE<br />

NO 02<br />

DATE : 22 APR 09 PAGE 2 OF 9<br />

4 Prior commencement of<br />

weld<strong>in</strong>g, The yard/<br />

Contractor must posses<br />

(a) WPS & PQR (b) As<br />

per WPS & PQR valid<br />

certificate for welders with<br />

their <strong>in</strong>dividual identity<br />

w.r.t certification while<br />

work<strong>in</strong>g (c) Proper<br />

weld<strong>in</strong>g equipments (d)<br />

Proper bak<strong>in</strong>g oven and<br />

hand oven (e) Correct<br />

consumable and process<br />

prescribed for the job.<br />

Ensure all the terms<br />

before f<strong>in</strong>alise the<br />

contract.<br />

5 Weld edge preparation /<br />

fair<strong>in</strong>g and gr<strong>in</strong>d<strong>in</strong>g of the<br />

area. Frames and<br />

longitud<strong>in</strong>al to be<br />

assessed / renewed,<br />

where ever possible<br />

template or mould to be<br />

prepared to manufacture<br />

new plate for renewal<br />

New plate to be prepared<br />

accord<strong>in</strong>g to the template<br />

or mould and prepare<br />

weld edge prior to lift the<br />

6<br />

plate & ensure plates and<br />

sections are detect free<br />

and SA­2.5 blasted and<br />

primed.<br />

7 Plate fit­up <strong>in</strong>spection i.e.<br />

tack welded all around<br />

with longitud<strong>in</strong>al, frames,<br />

Standard ship<br />

repair<strong>in</strong>g<br />

practices as per<br />

NES 155 or<br />

approved<br />

equivalent<br />

standards<br />

Standard ship<br />

repair<strong>in</strong>g<br />

practices as per<br />

NES 155 or<br />

approved<br />

equivalent<br />

standards<br />

Standard ship<br />

repair<strong>in</strong>g<br />

practices as per<br />

NES 155 or<br />

approved<br />

equivalent<br />

standards<br />

Standard ship<br />

repair<strong>in</strong>g<br />

practices as per<br />

1/<br />

2<br />

1/<br />

2<br />

1/<br />

2<br />

1/<br />

2<br />

3<br />

3 Check mis­match, root<br />

gap, weld edge,<br />

chamfer<strong>in</strong>g for different<br />

DYT/INCOD/12­13/106(a)/PL­YCM/MADHUR­REFIT/420 57/127