efurbishment, new<br />

<strong>in</strong>stallation and<br />

commission<strong>in</strong>g/Test<strong>in</strong>g<br />

of transformer /<br />

CT/PT<br />

miss<strong>in</strong>g /defects. ii) Body to be renewed / overhauled/<br />

repa<strong>in</strong>ted iii) Check for varnish of w<strong>in</strong>d<strong>in</strong>g & <strong>in</strong>sulation &<br />

ohmic value. iv) Check for fitment, tightness of<br />

connections & secure with earth<strong>in</strong>g of transformer .<br />

v) Check for operational and load performance<br />

NAVAL DOCKYARD, MUMBAI<br />

TITLE : QUALITY ASSURANCE PLAN DOC CODE Q C L 7 4 Q A P 0 6 3<br />

DEPT. :<br />

QC(ELECTRICAL )<br />

C. NO. 74 ISSUE NO : 00 DATE : 15 Apr 12 PAGE 05 OF 14<br />

Sr. ACTIVITY<br />

No. DESCRIPTION<br />

REFERENCE DOCMENT & CHECK LIST INSPECTION<br />

SCOPE OF WORK P R W H<br />

06 Repair, Overhaul<strong>in</strong>g,<br />

refurbishment, new<br />

<strong>in</strong>stallation and<br />

Refer to QAP : QCL074QAP059 for control panels.<br />

i) Visual checks after open<strong>in</strong>g for any defects<br />

ii) Check for overhaul<strong>in</strong>g, repair<strong>in</strong>g and clean<strong>in</strong>g of control<br />

1 2&3 3 3<br />

commission<strong>in</strong>g/Test<strong>in</strong>g panels. iii) Check defective /miss<strong>in</strong>g competent to be<br />

renewed as per sample / OEM make/ reputed make. iv)<br />

of Control panels<br />

Check for fitment, connection, secure & tightness of<br />

control panels. New material bill to be submitted v)<br />

Overload relay to be calibrated<br />

vi) New material compartment to be offered the QC check<br />

prior to fitment. vii) Operational performance to be<br />

checked as per Tech. manual & data.<br />

07 Repair, Overhaul<strong>in</strong>g,<br />

refurbishment, new<br />

<strong>in</strong>stallation and<br />

commission<strong>in</strong>g/Test<strong>in</strong>g<br />

of Self Starter /<br />

Battery charg<strong>in</strong>g<br />

Alternator / Dynamo<br />

i) Visual checks after open<strong>in</strong>g for any defects for<br />

serviceability.<br />

ii) Check for overhaul<strong>in</strong>g, repair<strong>in</strong>g and clean<strong>in</strong>g / renewal.<br />

iii) Check defective /miss<strong>in</strong>g competent to be renewed as<br />

per sample / OEM make/ reputed make. iv) Check for<br />

fitment, connection, secure & tightness. New material bill<br />

to be submitted v) If item /equipment found beyond<br />

repair to be renewed as per sample/make/ OEM<br />

make/rat<strong>in</strong>g.<br />

vi) New material compartment to be offered the QC check<br />

prior to fitment. vii) Operational performance to be<br />

checked as per Tech. manual & data. V)Test<br />

certificated to be produced / submitted. iv) Check for full<br />

DYT/INCOD/12­13/106(a)/PL­YCM/MADHUR­REFIT/420 71/127<br />