17<br />

cleared<br />

BLASTING Of<br />

UNDERWATER AREA<br />

Area to be washed by salt<br />

water followed by fresh<br />

water after undock<strong>in</strong>g<br />

2 3 3<br />

NAVAL DOCKYARD MUMBAI<br />

DOC CODE Q C H 7 4 Q A P 0 3 8<br />

DEPT : MQC ( HULL) C NO 74 ISSUE<br />

NO 02<br />

DATE : 22 APR 09 PAGE 5 OF 9<br />

18<br />

19<br />

20<br />

21<br />

22<br />

Underwater hull area to<br />

be prepared to SA 2.5 std<br />

by Grit blast<strong>in</strong>g<br />

2 3 3<br />

Areas to be primed with<strong>in</strong><br />

2 hrs of blast<strong>in</strong>g after QC<br />

2 3 3<br />

concurrence<br />

Application of pa<strong>in</strong>t<br />

scheme as per SOW No 20/03 2 3 3<br />

RENEWAL OF ANODES<br />

Determ<strong>in</strong>e No. of anodes<br />

to be renewed<br />

Identification of material<br />

Visual <strong>in</strong>spection<br />

report & Survey<br />

report<br />

Ship's record<br />

1 2<br />

1/2 3 3<br />

Iron grits to be used of<br />

G 24<br />

Inspection be offered<br />

at each coat <strong>in</strong>terval<br />

prior to next coat<br />

23<br />

Inspection after fitment of<br />

anodes<br />

As per <strong>in</strong>stallation<br />

manual. NDT post<br />

fitment<br />

2 3 3<br />

Areas where anodes<br />

are fitted to be blasted<br />

prior fitment<br />

FITTINGS<br />

24 Survey, Repair/ Renewal/<br />

Replacement/ of various<br />

foundations,<br />

miscellaneous out fitt<strong>in</strong>gs,<br />

Guard Rails, Hand Rails,<br />

Stanchions, Cable locker,<br />

Hawse pipe & Naval pipe,<br />

Bollard, Cleats,<br />

AS per SOW<br />

( If repair work is<br />

carried out then it<br />

has to follow the<br />

norms approved<br />

by QC)<br />

2 3 3 Structure which<br />

required renewal is<br />

manufactured as per<br />

approved draw<strong>in</strong>gs<br />

DYT/INCOD/12­13/106(a)/PL­YCM/MADHUR­REFIT/420 60/127