Table 20.1. SPI Slave Timing Parameters<br />

PARAMETER DESCRIPTIONMINMAX UNITS<br />

T SYSCLK System Clock Period (<strong>C8051F120</strong>/1/2/3) 10 ns<br />

T SYSCLK System Clock Period (<strong>C8051F124</strong>/5/6/7) 20 ns<br />

T SE NSS Falling to First SCK Edge (Slave Enable) 2*T SYSCLK ns<br />

T SD Last SCK Edge to NSS Rising (Slave Disable) 2*T SYSCLK ns<br />

T CKH SCK High Time 5*T SYSCLK ns<br />

T CKL SCK Low Time 5*T SYSCLK ns<br />

T SIS MOSIValid to SCK Active Edge (MOSISetup) 2*T SYSCLK ns<br />

T SIH SCK Active Edge to MOSIChange (MOSIHold) 2*T SYSCLK ns<br />

T SOH SCK Inactive Edge to MISO Change (MISO Hold) 4*T SYSCLK ns<br />