Supported multi-path c<strong>on</strong>figurati<strong>on</strong>s in a SAN envir<strong>on</strong>ment<br />

When discussing a supported c<strong>on</strong>figurati<strong>on</strong> with MPIO, you need to distinguish<br />

two different scenarios:<br />

►<br />

►<br />

One Virtual I/O Server attaching a LUN in the SAN over more than <strong>on</strong>e path.<br />

In this case, you <strong>on</strong>ly need to implement multi-path software <strong>on</strong> the Virtual I/O<br />

Server.<br />

Having multiple Virtual I/O Servers c<strong>on</strong>nect to the same LUN and backed up<br />

to the same client. In this case, the client partiti<strong>on</strong> uses MPIO to access the<br />

virtual disk as a single device. You may also c<strong>on</strong>sider using multi-path<br />

software <strong>on</strong> the Virtual I/O Server to access the LUN over more than <strong>on</strong>e path<br />

for path failover and load balancing.<br />

Note: This redbook <strong>on</strong>ly covers <strong>IBM</strong> storage soluti<strong>on</strong>s. For support statements<br />

of other storage vendors, c<strong>on</strong>tact your <strong>IBM</strong> representative or your storage<br />

vendor directly and ask for specificati<strong>on</strong>s <strong>on</strong> supported c<strong>on</strong>figurati<strong>on</strong>s.<br />

Supported <strong>IBM</strong> TotalStorage soluti<strong>on</strong>s<br />

At the time of writing, the TotalStorage Enterprise Server includes the following<br />

models:<br />

► 2105 Enterprise Storage Server® (models 800, 750, and Fxx)<br />

► 2107 Model 921 <strong>IBM</strong> TotalStorage DS8100<br />

► 2107 Model 922 <strong>IBM</strong> TotalStorage DS8300<br />

► 2107 Model 9A2 <strong>IBM</strong> TotalStorage DS8300<br />

► 2107 Model 92E <strong>IBM</strong> TotalStorage DS8000 Expansi<strong>on</strong> Unit<br />

► 2107 Model 9AE <strong>IBM</strong> TotalStorage DS8000 Expansi<strong>on</strong> Unit<br />

► 1750 Model 511 <strong>IBM</strong> TotalStorage DS6800<br />

► 1750 Model EX1 <strong>IBM</strong> TotalStorage DS6000 Expansi<strong>on</strong> Unit<br />

When attaching the Virtual I/O Server to a <strong>IBM</strong> TotalStorage DS Family, the<br />

RDAC driver is used <strong>on</strong> the Virtual I/O Server. At the time of writing, the <strong>IBM</strong><br />

TotalStorage DS Family include the following models:<br />

► DS4100 (FAStT100)<br />

► DS4200 (FAStT200)<br />

► DS4200 (FAStT600)<br />

► DS4400 (FAStT700)<br />

► DS4500 (FAStT900)<br />

► FAStT500 Storage Server<br />

242 <str<strong>on</strong>g>Advanced</str<strong>on</strong>g> <str<strong>on</strong>g>POWER</str<strong>on</strong>g> <str<strong>on</strong>g>Virtualizati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>IBM</strong> <strong>System</strong> <strong>p5</strong>