throughput and performance. For additi<strong>on</strong>al informati<strong>on</strong>, see <strong>IBM</strong><br />

<strong>System</strong> p <str<strong>on</strong>g>Advanced</str<strong>on</strong>g> <str<strong>on</strong>g>POWER</str<strong>on</strong>g> <str<strong>on</strong>g>Virtualizati<strong>on</strong></str<strong>on</strong>g> Best Practices,<br />

REDP-4194.<br />

• Improvements for altering virtual device capacity without disrupti<strong>on</strong>.<br />

When expanding the LUN size <strong>on</strong> an FC attached storage subsystem<br />

as well as extending a Logical Volume within a volume group, the<br />

Virtual I/O Server will detect this and the virtual SCSI server adapter<br />

will present this change to the virtual SCSI client adapter. Up<strong>on</strong><br />

recogniti<strong>on</strong> of the change, the volume group in the LPAR c<strong>on</strong>taining the<br />

hdisk represented by the LUN can take adavantage of the bigger disk<br />

with the command:<br />

# chvg -g volume_group<br />

and will immediately be able to use the additi<strong>on</strong>al storage capacity.<br />

This is valid for n<strong>on</strong>-rootvg disks <strong>on</strong>ly. The chvg command is not<br />

supported with rootvg, as stated in the manual page.<br />

• A c<strong>on</strong>figurable attribute that, when enabled, allows the virtual client<br />

adapter driver to determine the health of the VIOS to improve and<br />

expedite path failover processing.<br />

The vscsi_path_to attribute of the virtual SCSI client adapter was<br />

added. A value of 0 (default) disables it, while any other value defines<br />

the number of sec<strong>on</strong>ds the VSCSI client adapter will wait for<br />

commands issued to the VSCSI server adapter and not serviced. If that<br />

time is exceeded, the VSCSI client adapter attempts the commands<br />

again and waits up to 60 sec<strong>on</strong>ds until it fails the outstanding<br />

commands, writes an error to the error log and, if MPIO is used, tries<br />

another path to the disk. Therefore, this parameter should <strong>on</strong>ly be set<br />

for MPIO installati<strong>on</strong>s with dual Virtual I/O Servers.<br />

• VSCSI device error log enhancements.<br />

Virtual Ethernet and shared Ethernet adapter<br />

Ethernet support was enhanced in the following ways:<br />

– TCP Segmentati<strong>on</strong> Offload<br />

TCP segmentati<strong>on</strong> offload (large send) enables TCP large send capability<br />

(also known as segmentati<strong>on</strong> offload) from logical partiti<strong>on</strong>s to the physical<br />

adapter. The physical adapter in the SEA must be enabled for TCP<br />

largesend for the segmentati<strong>on</strong> offload from the LPAR to the SEA to work,<br />

and the SEA itself must be enabled for large send. Also, the operating<br />

system must be capable of performing a large send operati<strong>on</strong>. AIX 5L<br />

virtual Ethernet adapters are, by default, capable of large sends.<br />

You can enable or disable TCP large send <strong>on</strong> the SEA using the CLI chdev<br />

command. To enable it, use the -attr largesend=1 opti<strong>on</strong>. To disable it, use<br />

22 <str<strong>on</strong>g>Advanced</str<strong>on</strong>g> <str<strong>on</strong>g>POWER</str<strong>on</strong>g> <str<strong>on</strong>g>Virtualizati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>IBM</strong> <strong>System</strong> <strong>p5</strong>