Figure 5-23 shows that the virtual SCSI adapter in slot 30 is c<strong>on</strong>nected to the<br />

VIO_Server1 partiti<strong>on</strong>.<br />

Figure 5-23 LPAR properties window<br />

5. Disable the vscsi0 path for the hdisk0 using the chpath command.<br />

# lspath<br />

Enabled hdisk0 vscsi0<br />

Enabled hdisk0 vscsi1<br />

# chpath -l hdisk0 -p vscsi0 -s disable<br />

paths Changed<br />

# lspath<br />

Disabled hdisk0 vscsi0<br />

Enabled hdisk0 vscsi1<br />

Now we can start to update the VIO_Server1 partiti<strong>on</strong>.<br />

1. The Fix Pack 8 has been downloaded from the Virtual I/O Server support<br />

Web site at:<br />

http://techsupport.services.ibm.com/server/vios/download/home.html<br />