This completes the update of a redundant VIOS c<strong>on</strong>figurati<strong>on</strong> while maintaining<br />

client applicati<strong>on</strong> availability.<br />

5.4.2 Hot pluggable devices<br />

Similar to AIX 5L, the VIOS includes a feature that accepts hot plugging devices,<br />

such as disks and PCI adapters into the server, and activating them for the<br />

partiti<strong>on</strong> without a reboot.<br />

Prior to starting, an empty system slot must be assigned to the VIOS partiti<strong>on</strong> <strong>on</strong><br />

the HMC. This task can be d<strong>on</strong>e through dynamic LPAR operati<strong>on</strong>s, but the VIOS<br />

partiti<strong>on</strong> profile must also be updated so that the new adapter is c<strong>on</strong>figured to the<br />

VIOS after a reboot.<br />

To begin, use the diagmenu command to get into the VIOS diagnostic menu. This<br />

menu is very similar to the AIX 5L diagnostic menu and gives you the same four<br />

opti<strong>on</strong>s at the beginning screen:<br />

► Diagnostic Routines<br />

► <str<strong>on</strong>g>Advanced</str<strong>on</strong>g> Diagnostic Routines<br />

► Task Selecti<strong>on</strong><br />

► Resource Selecti<strong>on</strong><br />

The Hot Plug Tasks selecti<strong>on</strong> is under the Task Selecti<strong>on</strong> opti<strong>on</strong> of the menu.<br />

Under this menu selecti<strong>on</strong>, the choice of PCI hot plug tasks, RAID hot plug<br />

devices, and the SCSI and SCSI RAID hot plug manager are presented, as<br />

shown in Example 5-13.<br />

Example 5-13 Hot Plug Task diagmenu<br />

Hot Plug Task<br />

801004<br />

Move cursor to desired item and press Enter.<br />

PCI Hot Plug Manager<br />

RAID Hot Plug Devices<br />

SCSI and SCSI RAID Hot Plug Manager<br />

The PCI menu is used for adding, identifying, or replacing PCI adapters in the<br />

system that are currently assigned to the VIOS. The RAID hot plug devices<br />

opti<strong>on</strong> is used for adding RAID enclosures that will be c<strong>on</strong>nected to a SCSI RAID<br />

adapter. The SCSI and SCSI RAID manager menu is used for disk drive additi<strong>on</strong><br />

or replacement and SCSI RAID c<strong>on</strong>figurati<strong>on</strong>.<br />

Chapter 5. <strong>System</strong> management 305