Assigning <strong>on</strong>e VIOS as a client to the other for the DVD is not an opti<strong>on</strong>, because<br />

as of Virtual I/O Server 1.3 there can be <strong>on</strong>ly server SCSI adapters created in a<br />

Virtual I/O Server.<br />

5.4.5 Checking and fixing the c<strong>on</strong>figurati<strong>on</strong><br />

When using LVM mirroring between disks from two Virtual I/O Servers, a reboot<br />

of <strong>on</strong>e Virtual I/O Server makes <strong>on</strong>e disk missing and stale partiti<strong>on</strong>s have to be<br />

synchr<strong>on</strong>ized with the vary<strong>on</strong>vg command when the server is rebooted.<br />

When using NIB for network redundancy, the backup does not fall back to the<br />

primary adapter until the backup adapter fails. This holds for virtual adapters and<br />

AIX 5L V5.3-ML03 or higher even if Automatically Recover to Main Channel is set<br />

to yes due to the fact that no link up event is received during reactivati<strong>on</strong> of the<br />

path. This is because virtual Ethernet adapters are always up. If you c<strong>on</strong>figure<br />

NIB to do load balancing, you may want the NIB to be <strong>on</strong> the primary channel.<br />

If the settings are correct, MPIO will not require any special attenti<strong>on</strong> when a<br />

Virtual I/O Server is restarted, but a failed path should be checked.<br />

Checking and fixing these things in a system with many partiti<strong>on</strong>s is time<br />

c<strong>on</strong>suming and pr<strong>on</strong>e to errors.<br />

Figure 5-21 <strong>on</strong> page 295 is a sample script that you can fit to your needs that will<br />

check and fix the c<strong>on</strong>figurati<strong>on</strong> for:<br />

► Redundancy with dual Virtual I/O Servers and LVM mirroring<br />

►<br />

►<br />

Redundancy with dual Virtual I/O Servers, Fibre Channel SAN disks and AIX<br />

MPIO<br />

Network redundancy using Network Interface Backup<br />

The script should reside <strong>on</strong> each VIO Client and if using dsh (distributed shell), it<br />

should also be located in the same directory <strong>on</strong> each VIO Client.<br />

Since it is local to the VIO Client, it can be customized for the individual client.<br />

It could be executed at regular intervals using cr<strong>on</strong>.<br />

A better way would be to run the script <strong>on</strong> all required target partiti<strong>on</strong>s in parallel<br />

using dsh (distributed shell) from a NIM or admin server after a Virtual I/O Server<br />

reboot.<br />

Note: The dsh command is installed by default in AIX and is part of CSM.<br />

However, use of the full functi<strong>on</strong> clustering offered by CSM requires a license.<br />

See the AIX 5L documentati<strong>on</strong> for dsh command informati<strong>on</strong>.<br />