Example 5-48 Stopping ftp and telnet services <strong>on</strong> the Virtual I/O Server<br />

$ stopnetsvc telnet<br />

0513-127 The telnet subserver was stopped successfully.<br />

$ stopnetsvc ftp<br />

0513-127 The ftp subserver was stopped successfully.<br />

$<br />

To enable data transfer to the Virtual I/O Server using scp, see 6.2.2, “Install and<br />

c<strong>on</strong>figure SSL and SSH” <strong>on</strong> page 382.<br />

Using viosecure for finer grained c<strong>on</strong>trol of network security<br />

The viosecure command, available with Virtual I/O Server Versi<strong>on</strong> 1.3, allows for<br />

fine grained c<strong>on</strong>trol of network settings in terms of allowed and denied ports as<br />

well as for specifying which remote machine can c<strong>on</strong>nect to which port. The<br />

usage message shows which flags are supported (Example 5-49).<br />

Example 5-49 Usage message of the viosecure command<br />

$ viosecure<br />

Too few parameters.<br />

Usage: viosecure -level LEVEL [-apply] | [-n<strong>on</strong>int] -view<br />

viosecure -firewall <strong>on</strong> [[-force] -reload] | off<br />

viosecure -firewall allow | deny -port number [-interface<br />

ifname]<br />

[-address IPaddress] [-timeout Timeout] [-remote]<br />

viosecure -firewall view [-fmt delimiter]<br />

The viosecure command failed.<br />

$<br />

Chapter 5. <strong>System</strong> management 359