strong acid/bases, flames including welding sparks, temperature in excess of 71 0 c and any other<br />

environmental condition that maydamage the geotextile.<br />

Steps to be taken if geotextile roll or protective wrapping is damaged<br />

In most cases, damage to a roll of geotextile is limited to the protective wrapping. If the wrapping is<br />

damaged, proper storage of the geotextile is particularly critical. The rolls must be elevated off the<br />

ground surface and securely covered with a tarpaulin or opaque plastic sheet. If the outer layer of the<br />

geotextile itself is damaged, it is permissible during installation to remove the outermost wraps of the<br />

roll and discard the damaged material. The remaining undamaged material is suitable for use.<br />

Removing the outermost wrap of geotextile is also acceptable when a roll is exposed to sunlight for a<br />

period beyond that permitted by the project specifications. The remaining unexposed material is<br />

suitable for construction. Exposing geotextile rolls to moisture or water prior to installation can lead to<br />

serious handling problems. Non-woven geotextiles in particular can absorb water up to three times their<br />

weight. Further, the cores on which the geotextile rolls are wound are manufactured from laminated<br />

paper. When wet, the strength of these cores is seriouslydiminished to the point where the core will not<br />

support the weight of the geotextile.Consequently, it can be extremely difficult to install wet rolls of<br />

geotextile. In addition, it is nearly impossible to unroll wet, frozen geotextile without first allowing it to<br />

thaw. If geotextile rolls become wet, it is permissible to remove the waterproof cover to allow for a few<br />

days of exposure to wind in order to dry the fabric. It is essential that the rolls be elevated during the<br />

process. It is also possible to remove the protective wrapping from one end of the rolland elevate the<br />

opposite end of the roll. The majority of excess water will then flow out of the geotextile. In most<br />

cases, these procedures will not allow the fabric to dry completely. Once unrolled during installation, the<br />

geotextile will dry very quickly in the sun and wind. However, it should be noted that non-woven<br />

geotextiles used in conjunction with bitumen overlays of existing pavements must be completely dry<br />

prior to installation.<br />

702 GEOTEXTILES IN SUB-SURFACE DRAINS<br />

702.1 Scope<br />

This work shall consist of furnishing and placing a geotextile for the following drainage applications:<br />

edge of pavement drains; interceptor drains; wall drains; recharge basins, and relief wells. The<br />

geotextile shall be designed to allow passage of water while retaining in-situ soil without clogging. The<br />

work shall be carried out as per design drawings. The quantities of drainage Geotextiles as shown on<br />

the plans may be increased or decreased at the direction of the Engineer based on construction<br />

procedures and actual site conditions that occur during construction of project. Such variations in<br />

quantity will not be considered as alternatives in the details of construction or a change in the character<br />

of the work.<br />

702.2 Materials<br />

The geotextile fabric shall be a woven or non-woven fabric consisting of long-chain polymeric filaments<br />

or yarns such as polypropylene, polyethylene or polyester or any combination thereof, formed into a<br />

stable network such that the filaments or yarns retain their relative position to each other. These<br />

materials shall conform to the physical requirements of Table 700-3.<br />

All numeric values in Table 700-3 except AOS represent MARV in the weaker principal direction.<br />

Footnote of this Table 700-3 provides for a reduction in minimum property requirements when sufficient<br />

survivability information is available. The Engineer may also specify properties different from those<br />

listed in Table 2 based on engineering design and field experience.<br />

Table 700-3 Geotextile Requirements for Subsurface Drainage<br />

Per cent in-s<br />

itu soil<br />

passing<br />

0.075 mm<br />

sieve<br />

< 15<br />

15 to 50<br />

> 50<br />

Geotextile drainage property<br />

requirement<br />

Permittivity,<br />

per sec ASTM<br />

D 4491<br />

(Minimum ARV)<br />

0.5<br />

0.2<br />

0.1<br />

Apparent opening<br />

size, mm<br />

ASTM D 4751<br />

(Maximum ARV)<br />

0.43<br />

0.25<br />

0.22<br />

Recommended<br />

geotextile *<br />

Type II from<br />

Table 700-1