<strong>MAN</strong> B&W 6.04<br />

<strong>MAN</strong> B&W S65ME-C8-GI-TII<br />

Nominal rated engine (L 1 )<br />

High efficiency<br />

turbocharger (TCA)<br />

<strong>MAN</strong> <strong>Diesel</strong><br />

Page 4 of 12<br />

Example 1<br />

Specified MCR (M)<br />

Shaft power at MCR 17,220 kW 14,637 kW<br />

Engine speed at MCR at 95.0 r/min at 92.2 r/min<br />

Power of matching point %MCR 100% 90%<br />

Pumps:<br />

Fuel oil circulating pump m3 /h 6.8 6.8<br />

Fuel oil supply pump m3 /h 4.3 4.3<br />

Jacket cooling water pump m3 /h 145 145<br />

Central cooling water pump m3 /h 435 377<br />

Seawater pump m3 /h 540 461<br />

Lubricating oil pump m3 Coolers:<br />

Scavenge air cooler<br />

/h 345 345<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 7,150 5,942<br />

Central water quantity m3 Lub. oil cooler<br />

/h 252 209<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 1,360 1,247<br />

Lubricating oil quantity m3 /h 345 345<br />

Central water quantity m3 Jacket water cooler<br />

/h 183 168<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 2,490 2,204<br />

Jacket cooling water quantity m3 /h 145 145<br />

Central water quantity m3 Central cooler<br />

/h 183 168<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 11,000 9,393<br />

Central water quantity m3 /h 435 377<br />

Seawater quantity m3 /h 540 461<br />

Fuel oil heater: kW 180 180<br />

Gases at ISO ambient c<strong>on</strong>diti<strong>on</strong>s*<br />

Exhaust gas amount kg/h 154,200 131,400<br />

Exhaust gas temperature °C 240 232.8<br />

Air c<strong>on</strong>sumpti<strong>on</strong><br />

Starting air system: 30 bar (gauge)<br />

Reversible engine<br />

kg/s 42.0 35.8<br />

Receiver volume (12 starts) m3 2 x 7.0 2 x 7.0<br />

Compressor capacity, total m3 N<strong>on</strong>-reversible engine<br />

/h 420 420<br />

Receiver volume (6 starts) m3 2 x 3.5 2 x 3.5<br />

Compressor capacity, total m3 /h 210 210<br />

Exhaust gas tolerances: temperature ±15 °C and amount ±5%<br />

The air c<strong>on</strong>sumpti<strong>on</strong> and exhaust gas figures are expected and refer to 100% specified MCR,<br />

ISO ambient reference c<strong>on</strong>diti<strong>on</strong>s and the exhaust gas back pressure 300 mm WC<br />

The exhaust gas temperatures refer to after turbocharger<br />

* Calculated in example 3, in th<str<strong>on</strong>g>is</str<strong>on</strong>g> chapter<br />

Example 1 – Capacities of derated 6S65ME-C8-GI-TII with high efficiency <strong>MAN</strong> <strong>Diesel</strong> turbocharger type TCA and<br />

central cooling water system.<br />

198 74 50-1.0