<strong>MAN</strong> B&W 16.02<br />

Safe c<strong>on</strong>diti<strong>on</strong>/<br />

purged system<br />

Start of auxiliary<br />

equipment<br />

Purging<br />

Safe c<strong>on</strong>diti<strong>on</strong><br />

If the failure relates to the purging system it may<br />

be necessary to carry out purging manually before<br />

an engine repair <str<strong>on</strong>g>is</str<strong>on</strong>g> carried out. (<str<strong>on</strong>g>Th<str<strong>on</strong>g>is</str<strong>on</strong>g></str<strong>on</strong>g> will be<br />

explained later).<br />

The Dual Fuel C<strong>on</strong>trol system <str<strong>on</strong>g>is</str<strong>on</strong>g> a single system<br />

without manual back�up c<strong>on</strong>trol.<br />

However, the following equipment <str<strong>on</strong>g>is</str<strong>on</strong>g> made redundant<br />

to secure that a single fault will not cause<br />

fuel gas stop:<br />

• The communicati<strong>on</strong> network <str<strong>on</strong>g>is</str<strong>on</strong>g> doubled in order<br />

to minimize the r<str<strong>on</strong>g>is</str<strong>on</strong>g>k of interrupting the communicati<strong>on</strong><br />

between the c<strong>on</strong>trol units.<br />

• Vital sensors are doubled and <strong>on</strong>e set of these<br />

sensors <str<strong>on</strong>g>is</str<strong>on</strong>g> c<strong>on</strong>nected to the Plant C<strong>on</strong>trol and<br />

the other to the Safety System. C<strong>on</strong>sequently<br />

a sensor failure which <str<strong>on</strong>g>is</str<strong>on</strong>g> not detectable <str<strong>on</strong>g>is</str<strong>on</strong>g> of no<br />

c<strong>on</strong>sequence for safe fuel gas operati<strong>on</strong>.<br />

C<strong>on</strong>trol Unit Hardware<br />

Start of fuel<br />

gas supply<br />

Stop to safe<br />

c<strong>on</strong>diti<strong>on</strong><br />

Fig. 16.02.02: Fuel gas operati<strong>on</strong> state model<br />

Running <strong>on</strong><br />

fuel gas<br />

178 53 70�4.0<br />

For the Dual Fuel C<strong>on</strong>trol System two different<br />

types of hardware are used: the Multi Purpose<br />

C<strong>on</strong>troller Units and the GCSU, both developed<br />

by <strong>MAN</strong> B&W <strong>Diesel</strong> A/S.<br />

The Multi Purpose C<strong>on</strong>troller Units are used for<br />

the following units: GECU, GACU, GCCU, and the<br />

GSSU. In the following a functi<strong>on</strong>ality descripti<strong>on</strong><br />

for each units <str<strong>on</strong>g>is</str<strong>on</strong>g> given, see also Fig. 16.02.01.<br />

Gas Main Operating Panel (GMOP)<br />

Page 3 of 4<br />

For the GI c<strong>on</strong>trol system an extra panel called<br />

GMOP <str<strong>on</strong>g>is</str<strong>on</strong>g> introduced. From here all manually operati<strong>on</strong>s<br />

can be initiated. For example the change<br />

between the different running modes can be d<strong>on</strong>e<br />

and the operator has the possibility to manually<br />

initiate the purging of the gas pipes system with<br />

inert gas.<br />

Additi<strong>on</strong>ally it c<strong>on</strong>tains the facilities to manually<br />

start up or to stop <strong>on</strong> fuel gas.<br />

GECU, Plants c<strong>on</strong>trol<br />

The GECU handles the Plant C<strong>on</strong>trol and in combinati<strong>on</strong><br />

with GCCU it also handles Fuel C<strong>on</strong>trol.<br />

Example: When ‘dual fuel’ Start <str<strong>on</strong>g>is</str<strong>on</strong>g> initiated manually<br />

by the operator, the Plant C<strong>on</strong>trol will start<br />

the automatic start sequence which will initiate<br />

start�up of the sealing oil pump. When the<br />

engine c<strong>on</strong>diti<strong>on</strong> for Dual Fuel running, which <str<strong>on</strong>g>is</str<strong>on</strong>g><br />

m<strong>on</strong>itored by the GECU, <str<strong>on</strong>g>is</str<strong>on</strong>g> c<strong>on</strong>firmed to meet the<br />

prescribed demands, the Plant C<strong>on</strong>trol releases<br />

a ‘Start Dual Fuel Operati<strong>on</strong>’ signal for the GCCU<br />

(Fuel C<strong>on</strong>trol).<br />

In combinati<strong>on</strong> with the GCCU, the GECU will effect<br />

the fuel gas injecti<strong>on</strong> if all c<strong>on</strong>diti<strong>on</strong>s for Dual<br />

Fuel running are fulfilled.<br />

The Plant C<strong>on</strong>trol m<strong>on</strong>itors the c<strong>on</strong>diti<strong>on</strong> of the<br />

following:<br />

• HC ‘Sensors’<br />

• Gas Supply System<br />

• Sealing Oil System<br />

• Pipe Ventilati<strong>on</strong><br />

• Inert Gas System<br />

• Network c<strong>on</strong>necti<strong>on</strong> to other units of the Dual<br />

Fuel System<br />

and, if a failure occur, the Plant C<strong>on</strong>trol will automatically<br />

interrupt fuel gas start operati<strong>on</strong> and<br />

return the plant to Gas Safe C<strong>on</strong>diti<strong>on</strong>.<br />

The GECU also c<strong>on</strong>tains the Fuel C<strong>on</strong>trol which<br />

includes all facilities required for calculating the<br />

fuel gas index and the Pilot Oil index based <strong>on</strong> the<br />

command from the c<strong>on</strong>venti<strong>on</strong>al governor and the<br />

actual active mode.<br />

<strong>MAN</strong> B&W ME/ME-C/ME-B/-GI engines 198 50 61-9.1<br />

<strong>MAN</strong> <strong>Diesel</strong>