<strong>MAN</strong> B&W 1.04<br />
Engine Power Range and Fuel Oil C<strong>on</strong>sumpti<strong>on</strong><br />
Engine Power<br />
The following tables c<strong>on</strong>tain data regarding the<br />
power, speed and specific fuel oil c<strong>on</strong>sumpti<strong>on</strong> of<br />
the engine.<br />
Engine power <str<strong>on</strong>g>is</str<strong>on</strong>g> specified in kW for each cylinder<br />
number and layout points L 1 , L 2 , L 3 and L 4 :<br />
For c<strong>on</strong>versi<strong>on</strong>s between kW and metric horsepower,<br />
please note that 1 BHP = 75 kpm/s = 0.7355<br />
kW.<br />
L 1 designates nominal maximum c<strong>on</strong>tinuous rating<br />
(nominal MCR), at 100% engine power and 100%<br />
engine speed.<br />
L 2 , L 3 and L 4 designate layout points at the other<br />
three corners of the layout area, chosen for easy<br />
reference.<br />
Power<br />
L3<br />
L4<br />
L 1<br />
L 2<br />
Speed<br />
178 51 48�9.0<br />
Fig. 1.04.01: Layout diagram for engine power and speed<br />
Overload corresp<strong>on</strong>ds to 110% of the power at<br />
MCR, and may be permitted for a limited period of<br />
<strong>on</strong>e hour every 12 hours.<br />
The engine power figures given in the tables remain<br />
valid up to tropical c<strong>on</strong>diti<strong>on</strong>s at sea level as<br />
stated in IACS M28 (1978), i.e.:<br />
Blower inlet temperature ................................ 45 °C<br />
Blower inlet pressure ............................1,000 mbar<br />
Seawater temperature .................................... 32 °C<br />
Relative humidity ..............................................60%<br />
Specific Fuel Oil C<strong>on</strong>sumpti<strong>on</strong> (SFOC)<br />
Page 1 of 2<br />
The figures given in th<str<strong>on</strong>g>is</str<strong>on</strong>g> folder represent the values<br />
obtained when the engine and turbocharger<br />
are matched with a view to obtaining the lowest<br />
possible SFOC values while also fulfilling the IMO<br />
NOX Tier II em<str<strong>on</strong>g>is</str<strong>on</strong>g>si<strong>on</strong> limitati<strong>on</strong>s.<br />
Stricter em<str<strong>on</strong>g>is</str<strong>on</strong>g>si<strong>on</strong> limits can be met <strong>on</strong> <strong>request</strong>, using<br />
proven technologies.<br />
The SFOC figures are given in g/kWh with a tolerance<br />
of 5% and are based <strong>on</strong> the use of fuel with<br />
a lower calorific value of 42,700 kJ/kg (~10,200<br />
kcal/<br />
kg) at ISO c<strong>on</strong>diti<strong>on</strong>s:<br />
Ambient air pressure .............................1,000 mbar<br />
Ambient air temperature ................................ 25 °C<br />
Cooling water temperature ............................ 25 °C<br />
Specific fuel oil c<strong>on</strong>sumpti<strong>on</strong> varies with ambient<br />
c<strong>on</strong>diti<strong>on</strong>s and fuel oil lower calorific value. For<br />
calculati<strong>on</strong> of these changes, see Chapter 2.<br />
Gas c<strong>on</strong>sumpti<strong>on</strong><br />
The energy c<strong>on</strong>sumpti<strong>on</strong> (heat rate) for the ME�GI<br />
engine <str<strong>on</strong>g>is</str<strong>on</strong>g> the same whether running <strong>on</strong> gas in dual<br />
fuel mode (heat rate in kJ/kWh) or fuel <strong>on</strong>ly mode.<br />
<str<strong>on</strong>g>Th<str<strong>on</strong>g>is</str<strong>on</strong>g></str<strong>on</strong>g> means that when a given amount of fuel oil <str<strong>on</strong>g>is</str<strong>on</strong>g><br />
known in g/kWh, the additi<strong>on</strong>al gas c<strong>on</strong>sumpti<strong>on</strong><br />
can be found by c<strong>on</strong>verting the energy supplied<br />
as gas into cubic metre per hour according to the<br />
LCV of the gas.<br />
In the following <str<strong>on</strong>g>secti<strong>on</strong></str<strong>on</strong>g>s, the energy c<strong>on</strong>sumpti<strong>on</strong><br />
<str<strong>on</strong>g>is</str<strong>on</strong>g> calculated as equivalent fuel c<strong>on</strong>sumpti<strong>on</strong>, i.e.<br />
with all our usual figures.<br />
Example:<br />
SFOC ..................................................... 170 g/kWh<br />
ref. LCV .................................................... 42,700 kJ<br />
Heat rate .................0.170 x 42,700 = 7,259 kJ/kWh<br />
The heat rate <str<strong>on</strong>g>is</str<strong>on</strong>g> also referred to as the ‘Guiding<br />
Equivalent Energy C<strong>on</strong>sumpti<strong>on</strong>’.<br />
<strong>MAN</strong> B&W ME-GI engines 198 49 17-2.3<br />
<strong>MAN</strong> <strong>Diesel</strong>