Gas Compressor System<br />
The gas supply system <str<strong>on</strong>g>is</str<strong>on</strong>g> based <strong>on</strong> Flotech<br />
packaged compressors:<br />
• Low�pressure GE Oil & Gas RoFlo type gas<br />
compressors with lubricated vanes and oil<br />
buffered mechanical seals, which compress<br />
the cold boil�off gas from the LNG tanks at the<br />
temperature of –140 °C to –160 °C. The boil�off<br />
gas pressure in the LNG tanks should normally<br />
be kept between 1.06�1.20 bar(a). Under normal<br />
running c<strong>on</strong>diti<strong>on</strong>s, cooling <str<strong>on</strong>g>is</str<strong>on</strong>g> not necessary,<br />
but during start up, the temperature of the<br />
boil�off gas may have r<str<strong>on</strong>g>is</str<strong>on</strong>g>en to atmospheric temperature,<br />
hence pre�heating and after�cooling <str<strong>on</strong>g>is</str<strong>on</strong>g><br />
included, to ensure stabil<str<strong>on</strong>g>is</str<strong>on</strong>g>ati<strong>on</strong> of the cold inlet<br />
and intermediate gas. temperature<br />
• The high�pressure GE Oil & Gas Nuovo Pign<strong>on</strong>e<br />
SHMB type gas compressor; 4 throw,<br />
4�stage horiz<strong>on</strong>tally opposed and fully balanced<br />
crosshead type with pressure lubricated and<br />
water�cooled cylinders & packings, compresses<br />
the gas to approximately 250�300 bar, which <str<strong>on</strong>g>is</str<strong>on</strong>g><br />
the pressure required at the engine inlet at full<br />
load. Only reciprocating p<str<strong>on</strong>g>is</str<strong>on</strong>g>t<strong>on</strong> compressors<br />
are suitable for th<str<strong>on</strong>g>is</str<strong>on</strong>g> high�pressure duty; however<br />
the unique GE fully balanced frame layout<br />
addres�ses c<strong>on</strong>cerns about transmitted vibrati<strong>on</strong>s<br />
and also eliminates the need for heavy<br />
installati<strong>on</strong> structure, as <str<strong>on</strong>g>is</str<strong>on</strong>g> required with vertical<br />
or V�form unbalanced compressor designs. The<br />
d<str<strong>on</strong>g>is</str<strong>on</strong>g>charge temperature <str<strong>on</strong>g>is</str<strong>on</strong>g> kept at approx. 45 °C<br />
by the coolers.<br />
• Buffer tank/accumulators are installed to provide<br />
smoothing of minor gas pressure fluctuati<strong>on</strong>s<br />
in the fuel supply; ± 2 bar <str<strong>on</strong>g>is</str<strong>on</strong>g> required.<br />
• Gas inlet filter/separator with strainer for protecti<strong>on</strong><br />
against debr<str<strong>on</strong>g>is</str<strong>on</strong>g>.<br />
• D<str<strong>on</strong>g>is</str<strong>on</strong>g>charge separator after the final stage gas<br />
cooler for oil/c<strong>on</strong>densate removal.<br />
• Compressor capacity c<strong>on</strong>trol system ensures<br />
that the required gas pressure <str<strong>on</strong>g>is</str<strong>on</strong>g> in accordance<br />
with the engine load, and that the boil�off gas<br />
amount <str<strong>on</strong>g>is</str<strong>on</strong>g> regulated for cargo tank pressure<br />
c<strong>on</strong>trol (as described later).<br />
<strong>MAN</strong> <strong>Diesel</strong><br />
7.09<br />
Page 1 of 7<br />
• The compressor safety system handles normal<br />
start/stop, shutdown and emergency shutdown<br />
commands. The compressor unit includes a<br />
process m<strong>on</strong>itoring and fault indicati<strong>on</strong> system.<br />
The compressor c<strong>on</strong>trol system exchanges signals<br />
with the ME�GI c<strong>on</strong>trol system.<br />
• The compressor system evaluates the amount<br />
of <str<strong>on</strong>g>available</str<strong>on</strong>g> BOG and reports to the ME�GI c<strong>on</strong>trol<br />
system.<br />
Redundancy for the gas supply system <str<strong>on</strong>g>is</str<strong>on</strong>g> a very<br />
important <str<strong>on</strong>g>is</str<strong>on</strong>g>sue. Redundancy in an extreme sense<br />
means two of all comp<strong>on</strong>ents, but the costs are<br />
heavy and a lot of space <str<strong>on</strong>g>is</str<strong>on</strong>g> required <strong>on</strong> board the<br />
ship. We have worked out a recommendati<strong>on</strong> that<br />
reduces the costs and the requirement for space<br />
while ensuring a fully operati<strong>on</strong>al ME�GI engine.<br />
The dual fuel engine c<strong>on</strong>cept, in its nature, includes<br />
redundancy. If the gas supply system falls<br />
out, the engine will run <strong>on</strong> heavy fuel oil <strong>on</strong>ly.<br />
The gas supply system illustrated in Figs. 7.09.01<br />
and 7.09.02 are based <strong>on</strong> a 210,000 M3 LNG carrier,<br />
a boil off rate of 0.12 and equipped with 2<br />
dual fuel engines: 2 x 7S65ME�GI. For other sizes<br />
of LNG carriers the setup will be the same but the<br />
% will be changed. Fig. 7.09.03 shows the compressor<br />
system in more detail.<br />
Both systems compr<str<strong>on</strong>g>is</str<strong>on</strong>g>e a double (2 x 100%) set of<br />
Low Pressure compressors each with the capacity<br />
to handle 100% of the natural BOG if <strong>on</strong>e falls<br />
out (alternatively 3 x 50% may be chosen). Each<br />
of these LP compressors can individually feed<br />
both the High Pressure Compressor and the Gas<br />
Combusti<strong>on</strong> Unit. All compressors can run simultaneously,<br />
which can be util<str<strong>on</strong>g>is</str<strong>on</strong>g>ed when the engine<br />
<str<strong>on</strong>g>is</str<strong>on</strong>g> fed with both natural � and forced BOG.<br />
The HP compressor <str<strong>on</strong>g>secti<strong>on</strong></str<strong>on</strong>g> <str<strong>on</strong>g>is</str<strong>on</strong>g> chosen to be a<br />
single unit. If th<str<strong>on</strong>g>is</str<strong>on</strong>g> unit falls out then the ME�GI engine<br />
can run <strong>on</strong> Heavy Fuel Oil, and <strong>on</strong>e of the LP<br />
compressors can feed the GCU.<br />
Typical availability of these electrically driven Flotech<br />
/ GE Oil & Gas compressors <strong>on</strong> natural gas<br />
(LNG) service <str<strong>on</strong>g>is</str<strong>on</strong>g> 98%, c<strong>on</strong>sequently, an extra HP<br />
compressor <str<strong>on</strong>g>is</str<strong>on</strong>g> a high cost to add for the 2% extra<br />
availability.<br />
<strong>MAN</strong> B&W ME�GI engines ME�GI engines 198 48 85�8.4