Figure 10-8. Temperature Error of SQUID Bracket Temperature Control Test at August 8 2001 18:19-20:19Figure 10-9. Square Root of Power Spectrum Magnitude of the Temperature ErrorNonlinear readout behavior can cause biases which mimic the relativity signals. The signal from the gyroscopeis detected by the SQUID and since there is finite gain in the electronics, only a portion of this signal is nulled bythe feedback electronics. The associated error interacts with the SQUID’s nonlinear voltage vs. flux curve andcauses the signal to be distorted and aliased to dc. We have analyzed this phenomenon (Gutt et al., 1993) andhave achieved adequate readout system performance by requiring and attaining adequately linear SQUID292 March 2007 Chapter 10 — SQUID Readout Subsystem (SRE) Analysis