DateSeverity24 26-Apr-04 Obs F Noise on GSS FSU muxmonitors25 26-Apr-04 Obs F Transient temperatureincrease on the porousplug temperaturedifferential26 26-Apr-04 Minor LPS voltage trendingdownSubtypeTitle Description Root cause Corrective Action"hair" like data seen on allGSS health monitors; not onposition dataTemperatures have beenconsistently 4 mK apart. Asevere transient occurred 2to 3 mK apart.Corresponding GTtremendous drop of 0.3 K.Liquid point sensor, whichindicates possible porousplug breakthrough, wastrending toward yellowregion after TIV6 closure.Low level cross coupling ofmonitors in GSS forwardbox.Calibration of temperaturesensorSmall bias in liquid pointsensor data givingerroneous indication.None. Data is useable as is.Use independent means toverify a suspectedbreakthrough condtion.Use two independentmethods to identifybreakthrough conditions.27 27-Apr-04 Medium LV1 Neither Indicatesopen or closedAfter leakage vatterfly valve1 (LV1) initial opening,telemetry indicates that thevalve is in an intermediatestate, neither fully opened orclosedInsufficient durationspecified in valve commandtemplate to open valvecompletely.Increase duration to openand close the valve incommand templates.28 27-Apr-04 Obs N SAA Flag only set on halfof passes29 28-Apr-04 Obs F Station 200 TemperatureVariation30 28-Apr-04 Obs T SQUID 1, 3, 4 railedduring transition to gainlevel 5SAA Flag only getting sethalf the time it is expected tobe set.Temperature oscillation seenin SQUID bracketSQUID 1, 3, 4 railed duringtransition to gain level 531 29-Apr-04 Obs F TRE Data Spikes There are intermittent dataspikes in the TRE currenttelemetry.Flag only valid during guidestar valid per designGas in dewar wellTune-up issue with minimizelow pass filter algorithmRadiation events intelescope detector.32 29-Apr-04 Obs N SRE bus current jump SRE bus current jump Known issue with currentsensor used in SRENoneFlux flux will drive offresidual gas.Adjust algorithmparameters and re-deliverNoneNone528 March 2007 Chapter D — Summary Table of <strong>Flight</strong> Anomalies

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!