DateSeveritySubtypeTitle Description Root cause Corrective Action61 6-Jun-04 Obs F CCCA 10Hz Timeouts 3 CCCA 10Hz timeout eventshave been countedCCCA under high workoadat start of guide star valid.Occasional single instanceof 10 Hz interrupt overrundetected due to stackup ofCCCA processing tasks. Notand issue if overrun occursinfrequently.Watch62 6-Jun-04 Obs T Lost Star from ScienceTelescopeLost Star from ScienceTelescope in mode 1BRoot cause: bug with gyrobias averaging algorithm.Correct and re-deliver gyrobias algorithm (loaded withFSW 3.4.3)63 7-Jun-04 obs T Telescope star trackingnot adequate for scienceduring initial mode 1BcheckoutTelescope star tracking notadequate for scienceATC off-tune after initialguide star acquisitionOptimize ATC parameters64 8-Jun-04 obs F DC offset in SQUIDobserved during GSvalid/GS InvalidtransitionSmall SQUID output shiftsoccurred at shutteropen/close events onlywhen GSS is HV mode.Electromechanicalinteraction of suspensionwith SQUID.Watch; does not occur inGSS low voltage modes.65 9-Jun-04 obs F Delay in fwd acquisition,transponder yellow templimitDelay in fwd acquisition,transponder yellow templimitMost probable cause ofdelayed acquisition on fwdtransponder was frequencyshift caused by hightransponder temperature.None; temporary conditiondeveloped during item 11root cause investigation.66 11-Jun-04 Obs A GSS1 C axis control effortnoiseGSS1 Z axis control effortshows 10 nm "digital" typenoise occasionally seen;position spikes on Zcorrelate.Probable root cause:thermal issues on GSSsuspension cables. Does notshow up in scienceconfiguration.Watch.67 14-Jun-04 Obs F Gyro 2 dropped out ofdigitalGyro 2 dropped out ofdigitalLikely root cause: raceconditions in the analogarbiter state machine due toholding the gyro forextended periods near thelow backup threshold.when positioning gyro offcenter,stay 1um away frombackup threshold.<strong>Gravity</strong> <strong>Probe</strong> B — <strong>Post</strong> <strong>Flight</strong> Analysis • Final <strong>Report</strong> March 2007 533

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!