Figure 13-28 shows a correlation that increases with channel number and, equivalently, energy level. Onepossible explanation for this is that higher energy protons are more likely to penetrate through the spacecraftstructure to reach the detectorFigure 13-29 shows a similar plot using the data from the horizontal channels. Inthis case, the correlation function is inverse, meaning that the more high energy protons are seen by the PM, thefewer are seen by the telescope. Considering that the boresights of the two instruments are perpendicular, thiscan be explained knowing that direction of the trapped proton flux is approximately perpendicular to themagnetic field lines. Thus, if the telescope boresight is aligned with the magnetic field, many more protons willbe traveling perpendicular to it and parallel to the horizontal PM detector.Figure 13-29. Correlation between Horizontal PM Detector and Science Telescope (PXA)Figure 13-30 depicts the correlation coefficient vs. vertical channel number, but this time the data from thepositive TRE-A Y-axis detectors was used. A similar trend emerges.374 March 2007 Chapter 13 — Other Payload Subsystems Analyses