Figure 10-10. Quiescent SQUID Noise Data – On Orbit10.4.2 SQUID Bracket Temperature ControlThe two charts in Figure 10-11 below show the performance of the SQUID bracket temperature controller onorbit. Using the Bracket Temperature Control algorithm, the SQUID sensor temperature was controlled to 1.6micro K rms in a 3 mHz band about roll frequency. This is a factor of three below the required value of 5 microK rms, providing margin in the overall experiment error budget. This performance was achieved withoutimplementing the peaking filter at roll.294 March 2007 Chapter 10 — SQUID Readout Subsystem (SRE) Analysis