kIHC-S^u-Wi"v"u-Ti-u03 Rev. V<br />

,--,, 3.0 TESTING SCOPE AND DESCRIPTION<br />

The current focus of this test work is to verify the ability of various<br />

immobilization media to adequately solidify the waste feedstreams identified<br />

€or-WRAP--2A----The-base}}ne-destgn--as provid'd in the conceptual design for<br />

this facility was used as guidance in selecting which technologies should be<br />

applied for testing ( i.e., thermosetting polymer and cement based immobilization<br />

matrices). The following sections describe the logic in selecting the<br />

waste types and waste forms for testing, as well as a description of the<br />

testing approach. Detailed test plans are provided in the Appendixes A, B,<br />

and C.<br />

1 i erIrrrrnu ... • vc&co 1av^^ OF vr WASTE TYPES FOR TESTING<br />

Because of the lack of definition for some of the feedstreams identified<br />

for WRAP 2A, not all streams have been addressed in this initial testing<br />

phase. Instead, the approach taken was to address the large volume<br />

feedstreams that would have the greatest impact on facility design. These<br />

include 183H Basin Waste, LETF Secondary Solids (C-018 and L-045), and ash<br />

from thermal treatment. Together these represent the majority of the total<br />

feed to WRAP 2A. Certain other feedstreams, such as ion exchange resins and<br />

elemental lead, were not chosen for this testing phase because successful<br />

treatment of these streams has been sufficiently demonstrated commercially.<br />

The other smaller feedstreams for WRAP 2A will be tested at a later date.<br />

The specific waste types selected for this phase of testing are shown in<br />

Table 3-1.<br />

Feedstream<br />

number<br />

(test ID)<br />

Table 3-1. Initial Testing Phase of Large Volume Feedstreams.<br />

2A (Type 1) C-018 Ammonium sulfate<br />

1C (Type 2) 183H Sludge ( Basins 1 and 2)<br />

1C (Type 3) 183H Sludge ( Basins 3 and 4)<br />

lA (Type 4) 183H Crystalline solid<br />

1D (Type 5)<br />

183H Miscellaneous cleanup<br />

copper])<br />

Feedstream title<br />

(contaminated sandblast grit [high<br />

1D (Type 6) 183H Miscellaneous cleanup (sandblast grit [high nitrate])<br />

2C (Type 7) L-045 Metal sludge<br />

7 (Type 8) Ash from thermal treatment<br />