23.01.2013 Views

View Document Here - Hanford Site

View Document Here - Hanford Site

View Document Here - Hanford Site

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Stock Equipment Company<br />

FORMULATION DATA FOR EXOTHERMS<br />

Sample Binder<br />

(gms)<br />

WHC-SD-W100-TI-003 Rev. 0<br />

BPO<br />

(gms)<br />

DMT<br />

(gms)<br />

Waste<br />

(gms)<br />

Speed<br />

(rpm)<br />

Power<br />

watts<br />

peak<br />

tmp °C<br />

Control 100 2.58 0.1 0 500 0.1 105<br />

LETF 100 2.53 0.1 200 1800 14.6 67<br />

TYPE 2 100 T.50 2.0 100 1800 `` 11 5.7 70<br />

TYPE 3 100 2.60 0.1 200 1797 6.4 54<br />

TYPE 4 1 00 5. 1 6 1.1 150 180 3 5.7 64<br />

All the samples have been returned from the irradiation testing<br />

facility. The samples were tested for compressive strength.<br />

The compressive strength has increased for the samples tested.<br />

This increase is due to the probability of the embrittlement of<br />

the vinyl esther resin. Reference the attached Data Sheet for<br />

the results.<br />

We are currently collecting data toward preparation of the<br />

final report which will include the December Monthly Report.<br />

Awaiting purchase order revision concerning Westinghouse <strong>Hanford</strong> decision<br />

to proceed with additional testing.<br />

F-58<br />

...d=.