26<br />

V<br />

13<br />

13. Mounting the brackets for the upper flow sheets:<br />

Starting with the narrow vertical section (left or right), align the front<br />

edge of the first bracket with the front edge of the topmost opening in<br />

the vertical section (see figure above), then fix the bracket to the duct<br />

roof using 2 (or 3, as required) self-tapping screws (drill holes ø3.3 mm<br />

before). Mount the remaining brackets in an offset order (front/rear, see<br />

figure above).<br />

Important! Mount the bracket marked with a “V” between the vertical<br />

sections with system-specific width.<br />

14<br />

V<br />

ø3.3 mm<br />

ø3.3 mm<br />

ø3.3 mm<br />

14. Fix self-adhesive sealing plates to the two remaining angle brackets<br />

(see illustration above). Use the M6x12 hexagon socket screws provided<br />

to fix the angle brackets to the lower end of the two middle vertical<br />

sections. Push angle brackets down to the duct floor, then fasten M6x12<br />

hexagon socket screws. Now fix the angle brackets to the duct floor<br />

using two self-tapping screws provided (drill holes ø3.3 mm before).<br />

Important! Depending on the slope of the tub the angle brackets may<br />

need to be fixed to the vertical sections using the extensions provided<br />

(see enlarged section in the figure above).