46<br />

error XX<br />

XXXXXXXXXXXXXXXX<br />

<strong>Condair</strong> <strong>Dual</strong><br />

ready<br />

<strong>Condair</strong> <strong>Dual</strong><br />

humidific. on<br />

<strong>Condair</strong> <strong>Dual</strong><br />

flush.perm.circ.<br />

ext.safety chain<br />

interrupted<br />

error XX<br />

XXXXXXXXXXXXXXXX<br />

maintenance<br />

due<br />

Ag electrodes<br />

change due<br />

If a fault is detected during the system test, a corresponding error alert<br />

is triggered, i.e. the error indicator either flashes (alarm) or stays on<br />

(error), and a corresponding message appears on the display (also see<br />

chapter 7.1).<br />

After successful conclusion of the system test, the unit switches to<br />

standby mode and one of the following displays appears, depending<br />

on the current state of operation:<br />

– The <strong>Condair</strong> <strong>Dual</strong> is in standby mode (no humidification).<br />

– The <strong>Condair</strong> <strong>Dual</strong> humidifies (in addition, the “Humidification on”<br />

indicator lights).<br />

– Drain valve open, the permeate is led directly to the drain conduit<br />

(cause: preset flushing cycle is in progress (every 24 hrs.) or the<br />

conductance of the permeate is too high).<br />

If the external safety circuit (maximum hygrostat, flow control, etc.) is<br />

interrupted, the opposite message appears and the “Error” and “Humidification<br />

on” indicators light up intermittently.<br />

If a fault is detected during operation, a corresponding error alert is triggered,<br />

i.e. the error indicator either flashes (alarm) or stays on (error), and a<br />

corresponding message appears on the display (also see chapter 7.1).<br />

If maintenance is due or the silver ionization electrodes require replacement,<br />

the corresponding message and the current status display appear<br />

intermittently.<br />

– Maintenance due<br />

– Silver ionization electrodes worn<br />

Please consult chapter 6 for further information.<br />

Notes on operation<br />

– Make sure the minimum working pressure never drops below 2 bar<br />

during operation. In case the working pressure drops below the limit,<br />

check the reverse osmosis system and the fully demineralized water<br />

supply.<br />

– In standby mode the drain valve is opened for approximately 10<br />

seconds every 24 hours thus flushing the permeate supply conduit (for<br />

the sake of hygiene).<br />

– Humidification is not activated if the humidification request is below<br />

20% (2-valve connector box) or 15% (3-valve connector box), respectively.