28.02.2013 Views

R_Bibb_Medical_Modelling_The_Application_of_Adv.pdf

R_Bibb_Medical_Modelling_The_Application_of_Adv.pdf

R_Bibb_Medical_Modelling_The_Application_of_Adv.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

126 <strong>Medical</strong> modelling<br />

4. Eufi nger H, Wehmoller M (1998), ‘Individual prefabricated titanium implants<br />

in reconstructive crani<strong>of</strong>acial surgery: clinical and technical aspects <strong>of</strong> the fi rst<br />

22 cases’, Plastic Reconstructive Surgery, 102 (2), 300–308.<br />

5. Gateno J, Allen M E, Teichgraeber J F, Messersmith M L (2000), ‘An in vitro<br />

study <strong>of</strong> the accuracy <strong>of</strong> a new protocol for planning distraction osteogenesis<br />

<strong>of</strong> the mandible’, Journal <strong>of</strong> Oral and Maxill<strong>of</strong>acial Surgery, 58 (9), 985–<br />

90.<br />

6. Sailer H F, Haers P E, Zollik<strong>of</strong>er C P, Warnke T, Carls F R, Stucki P (1998),<br />

‘<strong>The</strong> value <strong>of</strong> stereolithographic models for preoperative diagnosis <strong>of</strong> crani<strong>of</strong>acial<br />

deformities and planning <strong>of</strong> surgical corrections’, International Journal <strong>of</strong><br />

Oral and Maxill<strong>of</strong>acial Surgery, 27 (5), 327–33.<br />

7. Hughes C W, Page K, <strong>Bibb</strong> R, Taylor J, Revington P (2003), ‘<strong>The</strong> custom made<br />

orbital fl oor prosthesis in reconstruction for orbital fl oor fractures’, British<br />

Journal <strong>of</strong> Oral and Maxill<strong>of</strong>acial Surgery, 41, 50–53.<br />

8. Heckmann S M, Winder W, Meyer M, Weber H P, Wichmann M G (2001),<br />

‘Overdenture attachment selection and the loading <strong>of</strong> implant and denture<br />

bearing area. Part 1: in vitro verifi cation <strong>of</strong> stereolithographic model’, Clinical<br />

Oral Implants Research, 12 (6), 617–23.<br />

9. Winder R J, Cooke R S, Gray J, Fannin T, Fegan T (1999), ‘<strong>Medical</strong> rapid<br />

prototyping and 3D CT in the manufacture <strong>of</strong> custom made cranial titanium<br />

plates’, Journal <strong>of</strong> <strong>Medical</strong> Engineering Technology, 23 (1), 26–8.<br />

10. Heissler E, Fischer F, Bolouri S, Lehmann T, Mathar W, Gebhardt A, Lanksch<br />

W, Bier J (1998), ‘Aesthetic and reconstructive surgery – custom-made cast<br />

titanium implants produced with CAD/CAM for the reconstruction <strong>of</strong> cranium<br />

defects’, International Journal <strong>of</strong> Oral and Maxill<strong>of</strong>acial Surgery, 27 (5),<br />

334–38.<br />

11. Minns R J, <strong>Bibb</strong> R, Banks R, Sutton R A (2003), ‘<strong>The</strong> use <strong>of</strong> a reconstructed<br />

three-dimensional solid model from CT to aid surgical management <strong>of</strong> a<br />

total knee arthroplasty: a case study’, <strong>Medical</strong> Engineering and Physics, 25,<br />

523–6.<br />

12. Munjal S, Leopold S S, Kornreich D, Shott S, Finn F A (2000), ‘CT generated<br />

3D models for complex acetabluar reconstruction’, Journal <strong>of</strong> Arthroplasty, 15<br />

(5), 644–53.<br />

13. Nakajima T (1995), ‘Integrated life-sized solid model <strong>of</strong> bone and s<strong>of</strong>t tissue:<br />

application for cleft lip and palate infants’, Plastic Reconstructive Surgery, 96<br />

(5), 1020–25.<br />

14. Schwaderer E, Bode A, Budach W, Claussen C D, Danmmann F, Kaus T,<br />

Plinkert P K (2000), ‘S<strong>of</strong>t-tissue stereolithography model as an aid to brachytherapy’,<br />

Medica Mundi, 44 (1), 48–51.<br />

15. Mankovich N J, Cheeseman A M, Stoker N G (1990), ‘<strong>The</strong> display <strong>of</strong> threedimensional<br />

anatomy with stereolithographic models’, Journal <strong>of</strong> Digital<br />

Imaging, 3 (3), 200–203.<br />

16. Erben C, Vitt K D, Wulf J (2000), ‘First statistical analysis <strong>of</strong> data collected in<br />

the Phidias validation study <strong>of</strong> stereolithography models’, Phidias Newsletter,<br />

5, 6–7.<br />

17. Sarment D P, Sukovic P, Clinthorne N (2003), ‘Accuracy <strong>of</strong> implant placement<br />

with a stereolithographic surgical guide’, International Journal <strong>of</strong> Oral and<br />

Maxill<strong>of</strong>acial Implants, 18 (4), 571–7.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!