3.8.9.2 External Parameters E40xxx<br />

128 words x 32 bits are addressed by E40000 to E40127.<br />

Parameters E400xx are written by the user programme. They are used to include signed numerical values which can<br />

be dimensions, offset, etc. for use in the in the part programme.<br />

External parameter MSB LSB<br />

E40000 %WA00 %WA01 %WA02 %WA03<br />

to<br />

E40031 %WA7C %WA7D %WA7E %WA7F<br />

E40032 %WB00 %WB01 %WB02 %WB03<br />

to<br />

E40063 %WB7C %WB7D %WB7E %WB7F<br />

E40064 %WC00 %WC01 %WC02 %WC03<br />

to<br />

E40095 %WC7C %WC7D %WC7E %WC7F<br />

E40096 %WD00 %WD01 %WD02 %WD03<br />

to<br />

E40127 %WD7C %WD7D %WD7E %WD7F<br />

3.8.9.3 Parameters E42xxx<br />

128 words addressed from E42000 to E42127. These parameters can be read from and written to by the user<br />

programme (<strong>function</strong>s R_E42000 (..) and W_E42000 (..)) and by the part programme. They are accessible for read<br />

and write using dynamic operators.<br />

REMARK There is no guarantee of coherence of the exchanges at system level (for instance,<br />

read by the machine processor can be interrupted by write by the CNC processor).<br />

It is therefore up to the user to provide a secure exchange mechanism.<br />