3.7.4.4 Watchdog %Qrc3B.0<br />

Must be programmed in the %INI task. When this bit is set, it indicates that output %Qrc00.0 of this card is a watchdog<br />

output.<br />

Two watchdogs are allowed. The monitor scans all of variables %Qrc3B.0 and selects the first two watchdogs<br />

programmed in increasing order (r,c).<br />

If the watchdog is not initialised, the general I/O card configuration error bit %R97F.1 (DEFCONF) is set, the inputs<br />

and outputs are no longer refreshed and the watchdog is reset.<br />

3.7.4.5 NC Access Enable %Qrc3B.1<br />

Enables or disables access to the output cards (by parameters E33xxx) and the input cards (by parameters E43xxx)<br />

by the part programmes.<br />

The variable equals 0 to inhibit access to the card by the part programme.<br />

The variable equals 1 to enable access to the card by the part programme.<br />

Variable %Qrc3B.1 is set to a default value of 0 by the monitor.<br />

REMARK %Qrc3B.1 must be programmed in %INI. Depending on the state of variable<br />

%W900.0, access to the outputs is enabled or inhibited by E33xxx.<br />