Variable Mnemonic Description<br />

%W3.0 C_RAZ Reset request. Also resets the PLC axes in case of a machine error.<br />

Taken into account if there is no movement on the axes.<br />

Variables<br />

REMARKS For processing of C_ARUS, C_CYCLE and C_RAX, refer to the Operator Manual.<br />

For processing of C_DGURG, refer to the Programming Manual.<br />

3.8.2.2 Latching Commands: %W4.W<br />

Variable Mnemonic Description<br />

%W4.7 VREDUIT Causes a switch to low speed<br />

Set to force the low speeds of movement set in words N3 and N4 of parameter<br />

P31 (see Parameter Manual).<br />

%W4.6 INIBUTIL Utility inhibit<br />

Set to inhibit access to the utilities.<br />

Reset to enable access to the utilities.<br />

%W4.5 C_UNIT Display units (metric or inch system)<br />

Set to enable dimension entry and display in inches.<br />

Reset to enable dimension entry and display in the metric system.<br />

%W4.4 PRESPUIS Motor power on.<br />

This variable is reset to indicate a synchronised axis motor power failure to the<br />

NC (after a synchronisation error).<br />

It is set to indicate power return and axis synchronisation enable to the NC.<br />

%W4.3 NARFIB No stop at end of block<br />

Enables execution of a CYCLE in the AUTO, SINGLE, MDI, DRYRUN modes and<br />

enables block sequencing in the AUTO and DRYRUN modes.<br />

Reset of this variable causes the cycle to stop at the end of execution of the<br />

current block.<br />

%W4.2 VITMAN2 Selection of rapid feed rates in <strong>manual</strong> modes 1 and 2<br />

%W4.1 VITMAN1 Enable selection of rapid feed rates in the JOG and HOME modes or setting the<br />

handwheel increment multiplier.<br />

The feed rates are modulated by the feed rate potentiometer.<br />

VITMAN1 VITMAN2 FEED RATE HANDWHEEL<br />

(Parameter P31) INCREMENT<br />

0 0 Normal JOG IU x 1<br />

0 1 Slow JOG IU x 100<br />

1 0 Fast JOG IU x 10<br />

1 1 Fast JOG Ui x 10<br />

%W4.0 AUTAV<br />

Where IU = internal system unit set by a machine parameter.<br />

Feed authorised on all the axis groups<br />

Enables movements in all the modes with movement.<br />

STOP in the CNC status window indicates that this operand is reset.<br />

%W5.7 SC_SAVE CNC screen on standby<br />

Set to enable the CNC screen to be placed on standby after five minutes of<br />

keyboard inactivity.<br />

Reset to inhibit the switch to standby of the screen and immediately reactivate the<br />

screen.<br />