workplaces. The MAK values have there<strong>for</strong>e been adjusted by suitable factors when deriving<br />

the LCI values <strong>for</strong> normal indoor living spaces (AgBB 2005). Table 27 shows exemplarily<br />

some AgBB-LCI values.<br />

Table 27: Some AgBB-LCI values in the LCI list as quoted in (ECA-EAQ. 2010)<br />

Substance CAS No. LCI [μg/m³] Remarks**<br />

12-1* 1.4-Dioxane 123-91-1 73 EU: Carc. Cat. 3<br />

12-2 Caprolactam 105-60-2 240 Individual substance evaluation<br />

12-3* N-Methyl-2-pyrrolidone 872-50-4 400<br />

12-4<br />

12-5<br />

Octamethylcyclotetrasiloxane<br />

(D4)<br />

Hexamethylene-tetramine<br />

(Formaldehyde-release )<br />

556-67-2 1200<br />

100-97-0 30<br />

EU: Repr. Cat 2 (31.ATP)<br />

Individual substance evaluation<br />

EU: Repr. Cat.3, Individual<br />

substance evaluation<br />

OELs Norway, Sweden: 3 000<br />

μg/m 3<br />

12-6 2-Butanonoxime 96-29-7 20<br />

EU: Carc. Cat. 3 Individual<br />

substance evaluation<br />

12-7* Tributyl phosphate 126-73-8 SVOC, EU: Carc. Cat. 3<br />

12-8* Triethyl phosphate 78-40-0 25<br />

cf. Tributyl phosphate (OELs<br />

Denmark, France: 2500 μg/m³,<br />

TLV (ACGIH): 2200 μg/m³)<br />

Figure 1 shows the amount of technical approvals according to the AgBB scheme up to now<br />

(status Sept 2010).<br />

Figure 1: Amount of technical approvals (in total 325; status 2010/9/1). Source: KIRCHNER<br />

(2010)<br />

Grenelle de l’environnement (France)<br />

According to MAUPETIT (2010) voluntary actions (product labels, EPDs, green building<br />

certification, NEHAP initiatives) have not been successful in France <strong>for</strong> providing in<strong>for</strong>mation<br />

on emissions of volatile compounds from building products. There<strong>for</strong>e m<strong>and</strong>atory<br />

requirements have been decided on in the framework of the “Grenelle de l’environnement”<br />

consensus action.<br />

Final Report 142 31 03 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!