IBO - <strong>Environmental</strong> <strong>and</strong> Health <strong>related</strong> Criteria <strong>for</strong> Buildings<br />
Energy <strong>and</strong> Resource Consumption” <strong>and</strong> “C <strong>Environmental</strong> Loadings” <strong>for</strong> a building e.g. in<br />
Ottawa, Canada:<br />
Energy-<strong>related</strong> indicators (B1-B3) account <strong>for</strong> 34% within the category “B Energy <strong>and</strong><br />
Resources” (8% within the whole <strong>criteria</strong>-catalogue), the residual issues within “Energy <strong>and</strong><br />
Resources” refer to materials (55%) <strong>and</strong> potable water (11%). Within the category “C<br />
<strong>Environmental</strong> Loadings” greenhouse gas <strong>and</strong> other atmospheric emissions caused by<br />
facility operations or production of construction materials account <strong>for</strong> 30% (weighting within<br />
the total system: 8%).<br />
Table 14: “Energy <strong>and</strong> CO2-emissions” <strong>related</strong> sub-categories <strong>and</strong> Weightings within<br />
sections “B Energy <strong>and</strong> Resources” <strong>and</strong> “C <strong>Environmental</strong> Loadings”, Example:<br />
Location Ottawa, Canada<br />
Weights<br />
within group<br />
Weights,<br />
total system<br />
Extent of<br />
pot. effect<br />
Intensity of<br />
pot. eff.<br />
Duration of<br />
pot. eff.<br />
Categories / Indicators<br />
22.5% B Energy <strong>and</strong> Resource Consumption<br />
18.2% B1 Total Life Cycle Non-Renewable Energy<br />
25% 1.0% 3 3 1 B1.1<br />
Annualized non-renewable primary energy<br />
embodied in construction materials.<br />
75% 3.1% 3 3 3 B1.2<br />
Annual non-renewable primary energy used<br />
<strong>for</strong> facility operations<br />
5.5% B2 Electrical peak dem<strong>and</strong> <strong>for</strong> facility operations<br />
10.9% B3 Renewable Energy<br />
50% 1.2% 3 3 1 B3.1<br />
Use of off-site energy that is generated from<br />
renewable sources.<br />
50% 1.2% 3 3 1 B3.2 Provision of on-site renewable energy syst.<br />
27.0% C <strong>Environmental</strong> Loadings<br />
15.6% C1 Greenhouse Gas Emissions<br />
25% 1.1% 3 3 1 C1.1<br />
Annualized GHG emissions embodied in<br />
construction materials.<br />
75% 3.2% 3 3 3 C1.2<br />
Annual GHG emissions from all energy used<br />
<strong>for</strong> facility operations.<br />
14.1% C2 Other Atmospheric Emissions<br />
52.9<br />
%<br />
23.5<br />
%<br />
23.5<br />
%<br />
2.0% 3 3 2 C2.1<br />
0.9% 2 2 2 C2.2<br />
0.9% 2 2 2 C2.3<br />
Emissions of ozone-depleting substances<br />
during facility operations.<br />
Emissions of acidifying emissions during<br />
facility operations.<br />
Emissions leading to photo-oxidants during<br />
facility operations.<br />
Final Report 61 31 03 2011