IBO - <strong>Environmental</strong> <strong>and</strong> Health <strong>related</strong> Criteria <strong>for</strong> Buildings<br />

Innovation credits that can be awarded <strong>for</strong> any one building assessed is 10; there<strong>for</strong>e the<br />

maximum available score achieved <strong>for</strong> ‘innovation’ is 10%.<br />

The credits are added together to produce an overall score on a scale of Pass, Good, Very<br />

Good, Excellent <strong>and</strong> Outst<strong>and</strong>ing.<br />

< 30% = Unclassified<br />

≥ 30% = Pass<br />

≥ 45% = Good<br />

≥ 55% = Very Good<br />

≥ 70% = Excellent<br />

≥ 85% = Outst<strong>and</strong>ing (besides >= 85% percentage score, there are additional requirements<br />

<strong>for</strong> achieving a BREEAM Outst<strong>and</strong>ing rating)<br />

To achieve a BREEAM rating, the minimum percentage score (>=30%) must be achieved<br />

<strong>and</strong> the minimum st<strong>and</strong>ards (i.e. number of credits achieved <strong>for</strong> specific sub-categories)<br />

applicable to that rating level complied with (see Table 4).<br />

Table 4: Minimum BREEAM st<strong>and</strong>ards<br />

BREEAM Rating /M<br />

BREEAM issue PASS GOOD VERY<br />

GOOD<br />

EXCEL-<br />

LENT<br />

Man 1 - Commissioning 1 1 1 1 2<br />

Man 2 - Considerate Constructors 1 2<br />

Man 4 - Building user guide 1 1<br />

Hea 4 - High frequency lighting 1 1 1 1 1<br />

Hea 12 - Microbial contamination 1 1 1 1 1<br />

Ene 1 - Reduction of CO2 emissions 6 10<br />

OUT-<br />

STANDING<br />

Ene 2 - Sub-metering of substantial<br />

1 1 1<br />

energy uses<br />

Ene 5 - Low or zero carbon<br />

1 1<br />

technologies<br />

Wat 1 - Water consumption 1 1 1 2<br />

Wat 2 - Water meter 1 1 1 1<br />

Wst 3 - Storage of recyclable waste 1 1<br />

LE 4 - Mitigating ecological impact 1 1 1<br />

More details to BREEAM schemes see http://www.breeam.org<br />

The issues of the Code CSH are summarized in 13.2 Appendix: Code <strong>for</strong> Sustainable Homes<br />

(CSH) .<br />

Final Report 30 31 03 2011