H12<br />

© Schneider Electric - all rights reserved<br />

H - LV switchgear: functions & selection<br />

Fig. H25 : Domestic-type circuit-breaker providing overcurrent<br />

protection and circuit isolation features<br />

Fig. H26 : Domestic-type circuit-breaker as above (Fig. H25)<br />

with incorparated protection against electric shocks<br />

OF1 SD SDE OF2<br />

OF2<br />

SDE<br />

SD<br />

OF1<br />

Fig. H28 : Example <strong>of</strong> a modular (Compact NS) industrial type<br />

<strong>of</strong> circuit-breaker capable <strong>of</strong> numerous auxiliary functions<br />

4 Circuit-breaker<br />

Some models can be adapted to provide sensitive detection (30 mA) <strong>of</strong> earthleakage<br />

current with CB tripping, by the addition <strong>of</strong> a modular block, while other<br />

models (RCBOs, complying with IEC 61009 and CBRs complying with IEC 60947-2<br />

Annex B) have this residual current feature incorporated as shown in Figure H26.<br />

Apart from the above-mentioned functions further features can be associated with<br />

the basic circuit-breaker by means <strong>of</strong> additional modules, as shown in Figure H27;<br />

notably remote control and indication (on-<strong>of</strong>f-fault).<br />

5<br />

4<br />

Schneider Electric - Electrical <strong>installation</strong> guide 2008<br />

3<br />

2<br />

O-OFF O-OFF - O-OFF -<br />

Fig. H27 : “Multi 9” system <strong>of</strong> LV modular switchgear components<br />

Moulded-case type industrial circuit-breakers complying with IEC 60947-2 are now<br />

available, which, by means <strong>of</strong> associated adaptable blocks provide a similar range <strong>of</strong><br />

auxiliary functions to those described above (see Figure H28).<br />

Heavy-duty industrial circuit-breakers <strong>of</strong> large current ratings, complying with<br />

IEC 60947-2, have numerous built-in communication and electronic functions<br />

(see Figure H29).<br />

In addition to the protection functions, the Micrologic unit provides optimized<br />

functions such as measurement (including power quality functions), diagnosis,<br />

communication, control and monitoring.<br />

Fig. H29 : Examples <strong>of</strong> heavy-duty industrial circuit-breakers. The “Masterpact” provides many<br />

automation features in its “Micrologic” tripping module<br />

1