MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

Action:<br />

6 – Other I/O error during positioning.<br />

An U0659 ABEND follows. This may be due to hardware problems with the tape drive. If<br />

it occurs with the same input tape on more than one tape drive, contact INNOVATION<br />

DATA PROCESSING for assistance.<br />

<strong>FDR</strong>605 COPY TERMINATED AT TAPE MARK SEQUENCE<br />

Reason: During a COPY with ALLFILES or MAXFILES=, <strong>FDR</strong>TCOPY found two consecutive<br />

tape marks following the trailer labels of the last file processed, indicating the end of<br />

the input tape(s).<br />

Action: None. This is a normal completion.<br />

<strong>FDR</strong>606 COPY TERMINATED BY FILE COUNT<br />

Reason: During a multi-file COPY, <strong>FDR</strong>TCOPY completed copying the number of files specified<br />

by the MAXFILES= operand.<br />

Action: None. This is a normal completion.<br />

<strong>FDR</strong>607 COPY TERMINATED BY END OF VOLUME LABELS<br />

Reason: During a COPY with ALLFILES or MAXFILES=, <strong>FDR</strong>TCOPY detected that the last file<br />

copied was followed by EOV (End-Of-Volume) labels rather than EOF (End-Of-File)<br />

labels, so <strong>FDR</strong>TCOPY is not able to continue. This probably means that the last file<br />

copied is not complete, which results in an <strong>FDR</strong>203 message.<br />

Action: None. This is not an error condition unless an <strong>FDR</strong>203 message is also printed to<br />

indicate that the last file copied was not a complete <strong>FDR</strong> backup.<br />

<strong>FDR</strong>609 CURRENT PAGEWIDTH(nnn) EXCEEDED BY vvv--action<br />

Reason: An <strong>FDR</strong>EPORT step specified PAGEWIDTH=nnn but the total length of the fields<br />

requested to be printed exceeds this value. If the output report DDname is not<br />

SYSPRINT, the output DCB is opened with a LRECL that corresponds to the page<br />

width. The result is truncation of the print line and the action is “PRINT LINE<br />

TRUNCATED”. If the report DDname is SYSPRINT, “PRINT LINE TRUNCATED”<br />

appears only if the actual LRECL of 121 is exceeded.<br />

Action: Increase the PAGEWIDTH, specify the AUTOSTACK operand to force eligible field<br />

stacking, or reduce the number of fields to be printed.<br />

<strong>FDR</strong>610<br />

Reason:<br />

Action:<br />

ICF CLUSTER TABLE FULL--ENTRY COUNT IS nnnnn--ICF SELECTION IS<br />

TERMINATED<br />

Selection of VSAM data sets is being performed by base cluster name utilizing a<br />

look-aside table of clusters. The table has been filled, and selection of additional<br />

VSAM data sets is no longer performed.<br />

See message <strong>FDR</strong>670.<br />

<strong>FDR</strong>615 dddddddd DSN=dsname FILE=fn VOL=vvvvvv status<br />

Reason: Printed by <strong>FDR</strong>TCOPY at the end of each file copied. One <strong>FDR</strong>615 message is printed<br />

for TAPEIN, TAPEOUT, and TAPE2OUT (if present). It documents the input or output<br />

DDname, data set name, file number (0 if on disk), and up to 20 volume serials.<br />

“status” is DROP if an input file was not copied due to being expired, or CATLG if an<br />

output file was successfully cataloged.<br />

CHAPTER 100 – PAGE 100-104 –