MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

<strong>FDR</strong>335 ABR BYPASSED RESTORE ON EXISTING DSN=dsname<br />

ANOTHER TASK COMPLETED RECALL OF DSN=dsname<br />

Reason: The first form of the message occurs when the PRESTAGE option was specified but the<br />

data set was found on the first output disk selected. The second form occurs when an<br />

auto-recall of an archived data set is requested but a previous request for the same<br />

data set is already recalling it.<br />

<strong>FDR</strong>336<br />

Reason:<br />

Action:<br />

DYNAMIC ALLOCATION ERROR COMP=cc, CODE=nnnn, INFO=iiii,<br />

DDNAME=ddname bypass<br />

<strong>FDR</strong> attempted to dynamically allocate (DYNALLOC) a disk volume or a data set (such<br />

as a disk or tape backup data set, the Archive Control File, or the <strong>FDR</strong>CRYPT<br />

Encryption Keyfile), but the allocation failed. “cc” is the return code in R15, “nnnn” is<br />

the dynamic allocation reason code, and “iiii” is the dynamic allocation information<br />

code. For z/OS, these codes are documented in the IBM manual Authorized<br />

Assembler Services Guide. They can also be found in Appendix A of the ISPF online<br />

HELP. Frequently encountered “nnnn” values include:<br />

0210 – Requested data set not available (e.g., another job had the Archive Control<br />

File with DISP=OLD).<br />

0218 – TSO user did not have MOUNT privileges to mount an ABR tape.<br />

021C – Invalid unit name used. ABR uses generic unit names, such as 3480, 3490,<br />

3590-1, 3390, etc. One common cause of this is an attempt to allocate a<br />

3480 cartridge on a system that no longer has 3480s in the configuration;<br />

contact INNOVATION DATA PROCESSING for a circumvention.<br />

0220 – Requested volume not available (e.g., another job is using a tape volume<br />

required by ABR).<br />

0484 – The operator replied “NO” to message IEF235D.<br />

04A8/04AC/04B0 – Allocation of a backup controlled by Oracle StorageTek’s<br />

ExHPDM product failed. It may be that the ExHPDM address space is not<br />

running, or the ExHPDM subsystem name is not “SOV”. If you use a<br />

different subsystem name, contact INNOVATION DATA PROCESSING.<br />

1708 – <strong>Data</strong> set not found in the catalog (e.g., the name in the ABR option table for<br />

the Archive Control File does not exist in the catalog).<br />

7700 – An error allocating a backup controlled by Oracle StorageTek’s ExHPDM<br />

product. It may be that the ExHPDM address space is not running. If it is,<br />

check the ExHPDM log for errors.<br />

“bypass” may be VOL=vvvvvv BYPASSED indicating that ABR bypassed processing the<br />

volume because of the error or DSN=dsname BYPASSED if a data set was bypassed.<br />

This volume or data set operation is bypassed. In some cases, the error can be avoided<br />

by setting the dynamic allocation flags in the <strong>FDR</strong> Global Options Table (see<br />

“ALLOCATEFLAG” in Section 90.15). If necessary, contact INNOVATION DATA<br />

PROCESSING for assistance.<br />

<strong>FDR</strong>337 ABR PRESTAGE--ALL DATA SETS ALREADY EXIST<br />

Reason: PRESTAGE was specified and all of the data sets to be restored were found to exist.<br />

Action: ABR terminates the operation with no data sets restored.<br />

<strong>FDR</strong>338<br />

Reason:<br />

Action:<br />

MAXIMUM BACKUP FILES EXCEEDED -- SPECIFY MAXBACKUP=nnnn TO OVERRIDE<br />

An ABR restore job was requested to restore data sets from more than the maximum separate<br />

backup data sets (default is 100 backup files). The restore job fails with an U0628 ABEND.<br />

Specify MAXBACKUP=nnnn on the RESTORE statement or eliminate some of the<br />

requested data sets to reduce the number of backup files required.<br />

<strong>FDR</strong>339 BACKUP OF ARCHIVE FILE WAS BYPASSED<br />

Reason: This is a warning that ABR either was unable to backup the Archive Control File, or was<br />

instructed not to, by the ARCBACKUP=NO operand.<br />