CHAPTER 100 – PAGE 100-127 –<br />

MESSAGES AND CODES<br />

COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />

CPK409E A REQUIRED OPERAND IS MISSING.<br />

Reason: An operand, either positional or keyword, required by the statement is missing.<br />

Action: Correct the error and rerun.<br />

CPK410E EITHER ’ENDSEQ’ COMMAND MISSING, OR POS=, DSG OR FILTER REQUESTED<br />

WITHIN A SEQUENCE SET. ASSUMING END OF SET<br />

Reason: 1.An ENDSEQ statement, delimiting a sequenced set, is missing.<br />

2.A SELECT statement with a POS= or SCRATCH= operand was encountered within<br />

the range of a SEQ statement. You cannot code the POS= operand for individual<br />

members of a sequenced set.<br />

3.A SELECT DSG= statement was encountered within the range of a SEQ statement.<br />

Action:<br />

An ENQSEQ statement is assumed before the incorrect statement. If this does not<br />

produce the correct results, correct the error and rerun.<br />

CPK411E THE FOLLOWING NAME WAS SPECIFIED MORE THAN ONCE -- dsname<br />

Reason: The data set name “dsname” was found on two or more SELECT statements. You may<br />

specify a particular data set name or data set name group only once.<br />

Action: Correct the error and rerun.<br />

CPK412W<br />

Reason:<br />

CPK413E<br />

Action:<br />

Reason:<br />

Action:<br />

THE ’RLSE=’ OPERAND WILL NOT BE HONORED WHEN ’POS=KEEP’ IS ALSO SPECIFIED.<br />

Specifying POS=KEEP makes data sets unmovable, so their unused tracks cannot be freed.<br />

None. This is only a warning message.<br />

VTOC POSITIONING/SIZING IS INVALID WHEN ’VTOC=NOCHANGE’ OR %FOLD IS<br />

ALSO SPECIFIED.<br />

A SELECT ***VTOC statement was input to move and/or resize the VTOC, but<br />

VTOC=COMPAKT was not specified on the COMPAKT statement. It is also invalid if<br />

%FOLD= is specified.<br />

Correct the error and rerun.<br />

CPK425E UNABLE TO PROCESS VOL=vvvvvv -- DUMMY VTOC OR CMS VOLUME<br />

Reason: COMPAKTOR found that the VTOC on volume “vvvvvv” started and ended on cylinder 0<br />

head 0. This is the form of a dummy VTOC created on volumes formatted for VM.<br />

Action: The dummy VTOC does not contain any useful information, so COMPAKTOR bypasses<br />

this volume.<br />

CPK426E UNABLE TO OPEN DDNAME=dddddddd -- POSSIBLE MISSING DD CARD<br />

Reason: COMPAKTOR is unable to open for access the DD statement whose name is<br />

“dddddddd”. This usually occurs when the DD statement is missing.<br />

Action: Supply the appropriate DD statement and rerun.<br />

CPK427E<br />

Reason:<br />

CPK428E<br />

Action:<br />

Reason:<br />

Action:<br />

THE DEVICE TO COMPAKT TO -- UNIT=uuuu, VOLSER=vvvvvv IS NOT<br />

SUPPORTED BY COMPAKTOR<br />

An unsupported disk device was referenced. See Section 2.10 “<strong>FDR</strong> Functions and<br />

Features” for a list of supported device types.<br />

If necessary, contact INNOVATION DATA PROCESSING for technical assistance.<br />

THE DEVICE DUMPED TO TAPE ON UNIT=uuuu,VOLSER=vvvvvv IS NOT<br />

SUPPORTED BY COMPAKTOR<br />

The internal device type code for the disk type on the backup tape is not among those<br />

supported.<br />

The backup tape may not be a valid <strong>FDR</strong> backup.<br />

Contact INNOVATION DATA PROCESSING for technical assistance.