MESSAGES AND CODES<br />

MESSAGES FROM SAR (<strong>FDR</strong>9NN) 100.4<br />

<strong>FDR</strong>970 CHAN CTRL ERROR uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

Reason: The channel reported a CHANNEL CONTROL CHECK. This indicates a hardware<br />

problem with the channel, channel cables, control unit, or I/O configuration.<br />

<strong>FDR</strong>971 INTERFACE ERROR uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

Reason: The channel reported an INTERFACE CONTROL CHECK. This indicates a hardware<br />

problem with the channel, channel cables, control unit, or I/O configuration.<br />

<strong>FDR</strong>972 CHAN DATA CHECK uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

Reason: The channel reported a CHANNEL DATA CHECK. This indicates a hardware problem<br />

with the channel or channel cables.<br />

<strong>FDR</strong>973<br />

Reason:<br />

NOISE RECORD uuuu cc statrcnt ssssssssssssssssssss<br />

The tape device reported reading a noise record, which is usually a record smaller than the<br />

minimum the device can handle. This is similar to a data check (see message <strong>FDR</strong>965).<br />

<strong>FDR</strong>974 PROGRAM CHECK uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

Reason: The channel reported a CHANNEL PROGRAM CHECK. This indicates a hardware<br />

problem or it may indicate an error in the CCWs used by SAR.<br />

<strong>FDR</strong>975<br />

Reason:<br />

PROTECTION CHECK uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

The channel reported an CHANNEL PROTECTION CHECK. This should not occur with SAR.<br />

<strong>FDR</strong>976 UNIT NOT CAPABLE uuuu cc statrcnt ssssssssssssssssssss<br />

Reason: A 3480 cartridge containing data compacted by the 3480 IDRC feature was mounted for<br />

restore, but the 3480 tape drive chosen did not have the IDRC feature installed.<br />

Action: If possible, choose a 3480 drive on another control unit that has the IDRC feature.<br />

<strong>FDR</strong>977 INCORRECT LENGTH uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

Reason: SAR requested that the device transfer data with a predetermined length, but the device<br />

reported that the length requested by SAR is different from the actual length of the<br />

data. This may indicate hardware errors on the device.<br />

<strong>FDR</strong>978 CHAINING CHECK uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

Reason: The channel reported a CHANNEL CHAINING CHECK. This indicates that an invalid<br />

CCW chain was issued and should not occur in SAR.<br />

<strong>FDR</strong>979 SEEK CHECK ERROR uuuu cc statrcnt ssssssssssssssssssss cccchhhh<br />

Reason: The disk device reported that the seek address (cylinder and head number of the track<br />

to be accessed) was invalid.<br />

Action: Verify that the correct device type and model were specified for the disk device.<br />