MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

<strong>FDR</strong>332 function SCRATCH status ON DSN=dsname<br />

Reason: An attempt to delete a non-VSAM data set FAILED or was BYPASSED. <strong>FDR</strong> deletes<br />

data sets during an <strong>FDR</strong>COPY MOVE, an Archive Backup (DUMP TYPE=ARC), or<br />

ABR Superscratch (DUMP TYPE=SCR).<br />

“status” of FAILED indicates that a SCRATCH SVC (for non-SMS data sets) or DELETE<br />

NVR or NONVSAM (for SMS-Managed data sets) failed to scratch this data set. An <strong>FDR</strong><br />

mini-dump is printed showing the registers and SCRATCH or DELETE parameter list.<br />

Action:<br />

For a non-SMS data set, the SCRATCH status code appears in the mini-dump, in the first line of<br />

the storage display after the registers, in the second byte of the last word (right most word).<br />

❖<br />

❖<br />

Code 1 indicates that the data set was not found in the VTOC.<br />

Code 7 indicates that SCRATCH failed because the data set was in use; this can<br />

be avoided by using the DSNENQ= option.<br />

❖ Code 2 or 8 indicates a security violation.<br />

For an SMS data set, register 15 (R15) contains the DELETE return code, and the<br />

reason code is in the last 2 bytes of the 6th word of the first line of the storage dump<br />

after the registers, in hex. These codes can be found under message IDC3009I in the<br />

IBM messages manual after converting the codes to decimal.<br />

❖ For Archive Backup, ABR has backed up the data set and recorded it in the<br />

Archive Control File. This data set may have been uncataloged or recataloged for<br />

recall as indicated by message <strong>FDR</strong>314.<br />

❖ For Superscratch, this data set may have been uncataloged as indicated by<br />

message <strong>FDR</strong>314.<br />

❖ For <strong>FDR</strong>COPY MOVE, if the data set was cataloged, it has been successfully<br />

recataloged and/or uncataloged.<br />

A “status” of BYPASSED indicates that the scratch was not attempted for this data set,<br />

because of an earlier error, such as a catalog error that is described by another message.<br />

If appropriate, scratch the data set manually. If desired, contact INNOVATION DATA<br />

PROCESSING for assistance.<br />

<strong>FDR</strong>333 CARD IMAGE--control statement image<br />

Reason: Displays a control statement read from an ABR remote queue data set (DDname<br />

ABRREST for RESTORE TYPE=ABR, ABRARCH for RESTORE TYPE=ARC,<br />

ABRBKDQ for DUMP TYPE=ABR/AUTO, ABRARDQ for DUMP TYPE=ARC).<br />

<strong>FDR</strong>334 <strong>FDR</strong> FAILED TO CATALOG comp DSN=dsname status<br />

Reason: <strong>FDR</strong> allocated and restored the non-VSAM data set “dsname”, but could not catalog it.<br />

If “comp” is printed, it is COMP=x'ffff00001111' that contains the catalog return codes<br />

from registers R15 (ffff), R0 (0000), and R1 (1111). If the register 15 value is x'FF14',<br />

then the code was generated by <strong>FDR</strong>, and indicates either that the data set was<br />

currently cataloged on zero volumes or more than 255 volumes, or that the volume<br />

sequence number of the current piece of the data set was higher than 255; the R0<br />

value is the number of volumes currently in the catalog entry (in hex). <strong>FDR</strong> supports<br />

cataloging of multi-volume data sets up to a maximum of 255 volumes.<br />

If “status” is ALREADY CATALOG VOL=vvvvvv then RECAT was not specified, and<br />

the output data set was already cataloged to a volume “vvvvvv” other than the output<br />

volume (or the input volume for a MOVE). For a multi-volume data set, “vvvvvv” is the<br />

volume in the catalog entry that corresponds to the volume sequence number of the<br />

portion of the data set that has just been processed.<br />

If “status” is NAME IS AN ALIAS then the data set name being cataloged was an alias<br />

of another data set in the catalog so <strong>FDR</strong> did not update it.<br />

Action: Determine the cause and take appropriate action. If desired, contact INNOVATION<br />

DATA PROCESSING for assistance.<br />