<strong>FDR</strong>020<br />

Reason:<br />

Action:<br />

MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

RACF VOLUME PROTECTION FAILED ON VOL=vvvvvv<br />

Security checking was enabled in the <strong>FDR</strong> Global Options Table. A full volume dump or restore<br />

was requested but a security call for class DASDVOL and volume “vvvvvv” failed. The user<br />

does not have sufficient authority to perform this operation. This message is produced only for<br />

full-volume restores and absolute track operations; full-volume backups and data set operations<br />

do class DATASET checks against individual data sets if the DASDVOL check fails.<br />

An U0801 ABEND is issued.<br />

<strong>FDR</strong>021 RACF DATA SET PROTECTION FAILED ON DSN=dsname<br />

Reason: Security checking was enabled in the <strong>FDR</strong> Global Options Table. A security call for<br />

class DATASET and data set name “dsname” failed. The user did not have sufficient<br />

authority to access this data set.<br />

Action: On a full volume backup operation, the backup is terminated. On a data set operation,<br />

this data set is bypassed.<br />

<strong>FDR</strong>022 RESTORE TAPE IS A DSF FORMATTED TAPE<br />

Reason: A full volume restore was requested from a backup created by an <strong>FDR</strong>DSF or <strong>FDR</strong>ABR<br />

data set backup. This backup may not contain an image of the entire volume.<br />

Action: Normally <strong>FDR</strong> terminates the RESTORE with an U0205 ABEND. If TAPE=DSF was coded<br />

on the RESTORE control statement, <strong>FDR</strong> continues the RESTORE. Warning messages<br />

are issued if the volume LABEL or VTOC are not found on the tape.<br />

<strong>FDR</strong>023 DUMMY VTOC READ -- ENTIRE PACK WILL BE DUMPED<br />

Reason: <strong>FDR</strong> found that the VTOC on this volume started and ended on cylinder zero head zero.<br />

This is the format used on volumes initialized by VM; that dummy VTOC is not valid.<br />

Action: <strong>FDR</strong> dumps all tracks on the volume.<br />

LINUX VOLUME VOL=volser<br />

Reason: This form of the <strong>FDR</strong>023 message indicates that <strong>FDR</strong> identified the volume as one that<br />

was formatted by Linux for the S/390 or System z system. The volume is in Linux<br />

Compatible Disk Layout (CDL) format with a VTOC in a special format.<br />

Action:<br />

<strong>FDR</strong> processes the Linux partitions that are identified by DSCBs in the Linux CDL VTOC.<br />

<strong>FDR</strong>024 INVALID EXTENT DESCRIPTOR [REASON=reason DSN=dsname]<br />

Reason: <strong>FDR</strong> read a DSCB (Format 1 or 3) that contained an invalid extent description. If a mini<br />

dump is printed, the first five bytes of the DSCB printed after the registers in the<br />

mini-dump are the cylinder, head, and record number (CCHHR) of the DSCB in error.<br />

If REASON= is printed, it is one of the following:<br />

1 – ENDING CYLINDER TOO LARGE<br />

2 – STARTING TRACK TOO LARGE<br />

3 – ENDING CCHH BEFORE BEGIN<br />

4 – ENDING TRACK TOO LARGE<br />

NOTE: Reasons “2” and “4” indicate that the starting or ending track number of an extent<br />

is higher than the highest track on a cylinder, i.e., higher than 14 on 3380 or 3390;<br />

not that the start or end of an extent is after the end of the pack.<br />

Action:<br />

Depending on the operation, <strong>FDR</strong> may continue the backup and dump all tracks on the<br />

volume, or may terminate with an U0110 ABEND.<br />

Scratch the bad data set.<br />

If an absolute track statement was specified (SELECT FROM/TO), the user specified a<br />

cylinder address greater than maximum cylinder number or a track number greater<br />

than the tracks per cylinder. Correct the SELECT statement.<br />

If necessary, contact INNOVATION DATA PROCESSING for assistance.<br />

CHAPTER 100 – PAGE 100-19 –