<strong>FDR</strong>224<br />
Reason:<br />
Action:<br />
MESSAGES AND CODES<br />
MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />
<strong>FDR</strong> VOL=vvvvvv IS BEING DUMPED FROM ONLINE UNIT BECAUSE<br />
SNAP/SPLIT/PSPLIT/FCOPY NEVER DONE<br />
A <strong>FDR</strong>ABR DUMP is being executed with SNAP=USE, PPRC=USE, FCOPY=USE,<br />
and/or BCV=USE but the identified volume is not eligible for <strong>FDR</strong>INSTANT<br />
processing. It is issued for every volume in the backup step that has not had a SNAP,<br />
SPLIT, PSPLIT, or FCOPY executed against it successfully.<br />
This message is issued for all normal volumes (volumes that you want regular backups,<br />
not <strong>FDR</strong>INSTANT) that are processed in the same step with <strong>FDR</strong>INSTANT volumes,<br />
unless you have erroneously attempted to do a SNAP, SPLIT, PSPLIT, or FCOPY of<br />
those ineligible volumes.<br />
The message is also issued for all eligible volumes for which SNAP, SPLIT, PSPLIT, or<br />
FCOPY has never been done, indicating that you want to backup those volumes normally.<br />
The volume is backed up by normal ABR backup processing, but it is not a point-in-time backup.<br />
If the message identifies a volume that you did not intend to backup with <strong>FDR</strong>INSTANT,<br />
it can be ignored.<br />
If you did intend to use <strong>FDR</strong>INSTANT on this volume, check your SNAP, SPLIT,<br />
PSPLIT, or FCOPY step to be sure that it was included.<br />
NOTE: If you attempted a SNAP, SPLIT, PSPLIT, or FCOPY but it failed for some reason,<br />
ABR fails that backup with message <strong>FDR</strong>211 REASON=E or F assuming that you<br />
wanted a point-in-time backup. Check the output of the SNAP, SPLIT, PSPLIT, or<br />
FCOPY step to determine the failure.<br />
<strong>FDR</strong>225 <strong>FDR</strong>INST DID NOT action OFFLINE type UNIT=uuuu - OFFLINE BACKUP IS IN USE<br />
Reason: A <strong>FDR</strong>ABR DUMP is being executed with SNAP=(USE,REL), PPRC=(USE,RET),<br />
FCOPY=(USE,REL) or BCV=(USE,RET) (or both) but at the end of the backup, ABR<br />
could not release the copied volume or RE-ESTABLISH the BCV because another<br />
task has the backup data set enqueued, probably because of a restore.<br />
Action: You should RE-ESTABLISH the BCV or release the copied volume later when the<br />
backup data set is no longer in use.<br />
<strong>FDR</strong>230 program type UNIT=uuuu REASON=reason<br />
Reason: <strong>FDR</strong>INSTANT had an error attempting to use special hardware facilities to get a<br />
point-in-time image of a volume for <strong>FDR</strong>INSTANT use. “type” is “WARNING” or<br />
“ERROR”. “uuuu” is the device address of the target disk and “reason” indicates the<br />
cause. Note that some reason codes have several versions depending on the<br />
hardware facility that failed. Reason codes include:<br />
1 MOUNT STATEMENT NOT SPECIFIED – There were no MOUNT statements<br />
following a SNAP, SPLIT, PSPLIT, or FCOPY statement. MOUNT statements are<br />
used to define the source volume and target device for the <strong>FDR</strong>INSTANT copy.<br />
2 MOUNT STATEMENT NOT FOUND – Some control statements were provided<br />
after the SNAP, SPLIT, PSPLIT, or FCOPY statement, but none of them were<br />
MOUNT statements. Only MOUNT statements can follow that statement.<br />
3 xxxxUNIT= NOT SPECIFIED IN MOUNT STATEMENT – A MOUNT<br />
statement does not contain the operand SNAPUNIT=, PPRCUNIT=,<br />
FLASHUNIT=, or BCVUNIT=. It is required.<br />
4 SOURCE AND type UNIT ADDRESS ARE EQUAL – The unit on which<br />
the volume specified by VOL= is mounted is the same as the unit specified<br />
by xxxxUNIT=. A volume cannot be copied to itself.<br />
5 INCOMPATIBLE SOURCE AND type UNIT DEVICE TYPES – The device<br />
type of the unit on which the volume specified by VOL= and the unit<br />
specified by xxxxUNIT= are not the same. You cannot snap from a 3380 to<br />
a 3390 or vice versa.<br />