MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

H MESSAGE ID=mmmm COMPLETION CODE=cccc REASON=rrrr –<br />

ECAM message number “mmmm” was issued to the SnapShot device. The<br />

message was rejected with completion code “cccc” and reason code “rrrr”.<br />

Contact INNOVATION DATA PROCESSING for assistance.<br />

I MESSAGE ID=mmmm PARMID=pppp COMP CODE=cccc REASON=rrrr –<br />

ECAM message number “mmmm” was issued to the SnapShot device. The<br />

message was rejected because of a problem with message parameter<br />

“pppp” with completion code “cccc” and reason code “rrrr”. Contact<br />

INNOVATION DATA PROCESSING for assistance.<br />

J<br />

TARGET UNIT HAS LESS CYLINDERS THAN SOURCE DEVICE – The<br />

source volume specified by VOL= has more cylinders than the target<br />

volume specified by SNAPUNIT=. The target volume must be equal to or<br />

larger than the source volume in size.<br />

K UNDEFINED SNAPSHOT STATUS – Unexpected response from the<br />

SnapShot device.<br />

L UNDEFINED SNAPSHOT MESSAGE COUNT – Unexpected response<br />

from the SnapShot device.<br />

M<br />

EXPECTED MSGID=nnnn. RECEIVED MSGID=nnnn – Unexpected<br />

response from the SnapShot device; the wrong ECAM message was received.<br />

N INVALID <strong>FDR</strong>INSTANT VOL1 LABEL OR GEN/CYCLE MISMATCH –<br />

<strong>FDR</strong> changed the ID of the volume label of the target disk to <strong>FDR</strong>1 so that it<br />

can't be accidentally brought online. When the point-in-time image was<br />

dumped, the label was no longer <strong>FDR</strong>1, or the ABR generation and cycle<br />

created during the SNAP, SPLIT, PSPLIT, or FCOPY was not the same as that<br />

currently recorded on the target. Contact INNOVATION DATA PROCESSING if<br />

you do not want <strong>FDR</strong>INSTANT to modify the volume label.<br />

O<br />

PRIOR <strong>FDR</strong>ABR INSTANT BACKUP PENDING DSN=dsname – A DUMP<br />

or SNAP, SPLIT, PSPLIT, or FCOPY was not done because a previous SNAP,<br />

SPLIT, PSPLIT, or FCOPY had been done, but you have not yet executed the<br />

DUMP to move the point-in-time backup to tape. If you want to do a DUMP<br />

(non-<strong>FDR</strong>INSTANT) and discard the point-in-time backup, specify the operand<br />

INSTANTLOSS=YES on the DUMP statement.<br />

P PRIOR <strong>FDR</strong>ABR INSTANT BACKUP IS LOST DSN=dsname – A DUMP<br />

or SNAP, SPLIT, PSPLIT, FCOPY detected that a previous SNAP, SPLIT,<br />

PSPLIT, FCOPY had been done, but you have not yet executed the DUMP to<br />

move the point-in-time backup to tape. Since you replied “YES” to the <strong>FDR</strong>W02<br />

message or specified CONFMESS=NO or INSTANTLOSS=YES, the<br />

uncompleted backup is discarded and is no longer usable.<br />

Q<br />

Q<br />

TOO MANY WRITES PENDING – While <strong>FDR</strong>COPY was attempting to use<br />

the EMCCOPY internal copy function on an EMC Symmetrix, the<br />

Symmetrix reported that an internal limit of pending writes (from cache to<br />

disk) was exceeded. The copy continues using normal read/write I/O.<br />

CONTROLLER DOES NOT SUPPORT LRE/WFT – Contact INNOVATION<br />

DATA PROCESSING for assistance.<br />

R TARGET VOLSER DOES NOT MATCH SOURCE – The operand<br />

VERIFYVOLSER=YES was specified, but the current volser of the offline<br />

target does not match the volser of the online source volume.<br />

R<br />

S<br />

DEVN/UNIT LOCATION ROUTINE ERROR FUNC=function – Contact<br />

INNOVATION DATA PROCESSING for assistance.<br />

PPRCUNIT IS NOT PAIRED WITH PRIMARY – The device specified by<br />

PPRCUNIT= is not currently in a PPRC session with the primary volume. You<br />

did not issue a previous (C)ESTPAIR command to establish the session.<br />

S ANTRQST IS NOT INSTALLED AT LEVEL 4 – You do not have the<br />

proper level of the IBM ANTRQST API to support FlashCopy installed.<br />

Contact INNOVATION DATA PROCESSING for assistance.<br />