MESSAGES AND CODES<br />
MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />
H MESSAGE ID=mmmm COMPLETION CODE=cccc REASON=rrrr –<br />
ECAM message number “mmmm” was issued to the SnapShot device. The<br />
message was rejected with completion code “cccc” and reason code “rrrr”.<br />
Contact INNOVATION DATA PROCESSING for assistance.<br />
I MESSAGE ID=mmmm PARMID=pppp COMP CODE=cccc REASON=rrrr –<br />
ECAM message number “mmmm” was issued to the SnapShot device. The<br />
message was rejected because of a problem with message parameter<br />
“pppp” with completion code “cccc” and reason code “rrrr”. Contact<br />
INNOVATION DATA PROCESSING for assistance.<br />
J<br />
TARGET UNIT HAS LESS CYLINDERS THAN SOURCE DEVICE – The<br />
source volume specified by VOL= has more cylinders than the target<br />
volume specified by SNAPUNIT=. The target volume must be equal to or<br />
larger than the source volume in size.<br />
K UNDEFINED SNAPSHOT STATUS – Unexpected response from the<br />
SnapShot device.<br />
L UNDEFINED SNAPSHOT MESSAGE COUNT – Unexpected response<br />
from the SnapShot device.<br />
M<br />
EXPECTED MSGID=nnnn. RECEIVED MSGID=nnnn – Unexpected<br />
response from the SnapShot device; the wrong ECAM message was received.<br />
N INVALID <strong>FDR</strong>INSTANT VOL1 LABEL OR GEN/CYCLE MISMATCH –<br />
<strong>FDR</strong> changed the ID of the volume label of the target disk to <strong>FDR</strong>1 so that it<br />
can't be accidentally brought online. When the point-in-time image was<br />
dumped, the label was no longer <strong>FDR</strong>1, or the ABR generation and cycle<br />
created during the SNAP, SPLIT, PSPLIT, or FCOPY was not the same as that<br />
currently recorded on the target. Contact INNOVATION DATA PROCESSING if<br />
you do not want <strong>FDR</strong>INSTANT to modify the volume label.<br />
O<br />
PRIOR <strong>FDR</strong>ABR INSTANT BACKUP PENDING DSN=dsname – A DUMP<br />
or SNAP, SPLIT, PSPLIT, or FCOPY was not done because a previous SNAP,<br />
SPLIT, PSPLIT, or FCOPY had been done, but you have not yet executed the<br />
DUMP to move the point-in-time backup to tape. If you want to do a DUMP<br />
(non-<strong>FDR</strong>INSTANT) and discard the point-in-time backup, specify the operand<br />
INSTANTLOSS=YES on the DUMP statement.<br />
P PRIOR <strong>FDR</strong>ABR INSTANT BACKUP IS LOST DSN=dsname – A DUMP<br />
or SNAP, SPLIT, PSPLIT, FCOPY detected that a previous SNAP, SPLIT,<br />
PSPLIT, FCOPY had been done, but you have not yet executed the DUMP to<br />
move the point-in-time backup to tape. Since you replied “YES” to the <strong>FDR</strong>W02<br />
message or specified CONFMESS=NO or INSTANTLOSS=YES, the<br />
uncompleted backup is discarded and is no longer usable.<br />
Q<br />
Q<br />
TOO MANY WRITES PENDING – While <strong>FDR</strong>COPY was attempting to use<br />
the EMCCOPY internal copy function on an EMC Symmetrix, the<br />
Symmetrix reported that an internal limit of pending writes (from cache to<br />
disk) was exceeded. The copy continues using normal read/write I/O.<br />
CONTROLLER DOES NOT SUPPORT LRE/WFT – Contact INNOVATION<br />
DATA PROCESSING for assistance.<br />
R TARGET VOLSER DOES NOT MATCH SOURCE – The operand<br />
VERIFYVOLSER=YES was specified, but the current volser of the offline<br />
target does not match the volser of the online source volume.<br />
R<br />
S<br />
DEVN/UNIT LOCATION ROUTINE ERROR FUNC=function – Contact<br />
INNOVATION DATA PROCESSING for assistance.<br />
PPRCUNIT IS NOT PAIRED WITH PRIMARY – The device specified by<br />
PPRCUNIT= is not currently in a PPRC session with the primary volume. You<br />
did not issue a previous (C)ESTPAIR command to establish the session.<br />
S ANTRQST IS NOT INSTALLED AT LEVEL 4 – You do not have the<br />
proper level of the IBM ANTRQST API to support FlashCopy installed.<br />
Contact INNOVATION DATA PROCESSING for assistance.<br />
CHAPTER 100 – PAGE 100-51 –