MESSAGES AND CODES<br />
COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />
CPK506E AUTHORIZATION CHECK FAILED<br />
Reason: The volume being COMPAKTed is defined to RACF with DASDVOL class protection,<br />
and the user id for this job does not have ALTER authority.<br />
Action: Authorize the user id to the volume, or run under an authorized user id.<br />
CPK507E INPUT TAPE HAS VTOC OR LABEL ERROR<br />
Reason: While executing a COMPAKT-from-backup, COMPAKTOR detected that the <strong>FDR</strong><br />
backup does not contain a valid VTOC or a valid disk volume label.<br />
Action: Use <strong>FDR</strong> to dump the volume again, and rerun COMPAKTOR.<br />
CPK508E<br />
Reason:<br />
Action:<br />
CPK DOES NOT SUPPORT DUMPCOMPRESSEDTRACK (DCT) FORMAT OR<br />
ENCRYPTED TAPE. USE <strong>FDR</strong> RESTORE.<br />
While executing a COMPAKT-from-backup, COMPAKTOR detected that the <strong>FDR</strong><br />
backup was created using:<br />
❖ <strong>FDR</strong>CRYPT encryption.<br />
COMPAKTOR cannot restore either of these formats.<br />
❖ Rerun the backup without <strong>FDR</strong>CRYPT and rerun COMPAKTOR.<br />
❖ Restore the backup with <strong>FDR</strong> and use FAST COMPAKTOR to do a COMPAKTin-place.<br />
CPK512I FORMAT 4 INDICATES VOLUME OCCUPIES nnnnnnnnn CYLINDERS<br />
Reason: The Format 4 DSCB (the VTOC Descriptor record) indicates that the volume has<br />
“nnnnnnnnn” cylinders, which is different from what COMPAKTOR expects for this<br />
disk type. This disk may be a VM mini-disk or a disk that contains a non-standard<br />
number of cylinders.<br />
This message is also issued if a disk volume was initialized with the wrong number of<br />
data cylinders or the wrong number of alternate tracks in the Format 4 DSCB. This<br />
might occur if:<br />
❖ A volume was moved from a disk device with alternate tracks to one with no<br />
alternate tracks, or vice versa (an <strong>FDR</strong> DUMP/RESTORE or COPY does not have<br />
this problem but other copy utilities may).<br />
❖ A volume was initialized with other than ICKDSF, such as a utility from your disk<br />
vendor.<br />
This message may be accompanied by message CPK519E because the incorrect<br />
counts may make COMPAKTOR think that a data set near the end of the volume<br />
occupies non-existent tracks. If so, fix the problem with the counts as described below<br />
and rerun COMPAKTOR to see if the CPK519E goes away.<br />
Action: COMPAKTOR honors the value from the F4 DSCB if it is less than what COMPAKTOR<br />
expects. Otherwise COMPAKTOR uses its expected value.<br />
If the data or alternate count was wrong, you can correct it:<br />
❖ An ICKDSF REFORMAT REFVTOC can be used to update the VTOC with the<br />
proper values without disturbing existing data. However the REFVTOC operand<br />
requires at least ICKDSF R16 plus a PTF. Check with IBM for the requirements<br />
and usage instructions for REFVTOC.<br />
❖ If you cannot do REFVTOC, move all data sets from the volume and re-initialize it<br />
with an ICKDSF minimal INIT.<br />
If you cannot do either, contact INNOVATION DATA PROCESSING for assistance.<br />