CPK322I<br />

MESSAGES AND CODES<br />

COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />

COMPAKTOR function ENDED.<br />

COMPAKTOR RECOVERY ENDED - DATA SETS RETURNED TO ORIGINAL LOCATIONS<br />

COMPAKTOR RECOVERY ENDED - REORGANIZATION COMPLETE<br />

Reason: Indicates that COMPAKTOR has completed the operation RECOVERY, RELEASE, or<br />

RESTORE and the volume should be usable. Some cleanup operations (such as<br />

mapping the COMPAKTed volume and rebuilding the VTOC Index) may still remain to<br />

be done, so errors may still occur.<br />

On a RESTORE from an <strong>FDR</strong> backup tape, if the text SOME BACKUP VOLUMES WERE<br />

NOT REQUIRED appears, this is simply an assurance that you need not be concerned if<br />

COMPAKTOR did not call for all the volumes of the <strong>FDR</strong> backup; tracks at the end of the<br />

volume did not need to be rewritten, probably because of %FOLD=nn or SIZEKEEP=.<br />

The second form of the message is issued when COMPAKTOR RECOVERY has completed<br />

by backing out all changes and returning all data to its original location on the disk.<br />

The third form of the message is issued when COMPAKTOR RECOVERY was able to complete<br />

the original COMPAKTOR request and has moved all data to its intended location.<br />

CPK403E EXCESSIVE NUMBER OF DATA SET AND/OR DSGROUP NAMES INPUTTED<br />

Reason: Over 255 different names were found on SELECT control statements.<br />

Action: Rerun with fewer SELECT control statements.<br />

CPK404W operand=value IS INVALID. A DEFAULT VALUE MAY BE ASSUMED<br />

Reason: The “value” is invalid for the “operand”.<br />

Action: Check for valid data or numeric data for the keyword, as described in Chapter 40<br />

“COMPAKTOR (CPK)”. If COMPAKTOR ABENDed, fix the invalid variable and rerun,<br />

otherwise check that the assumed default value is acceptable.<br />

CPK405E THE FROMDD= PARAMETER IS INVALID, OR ITS DD CARD IS MISSING, OR IT<br />

DOES NOT SPECIFY A type DEVICE, OR VOL= WAS SPECIFIED<br />

Reason: You specified FROMDD= but:<br />

❖ The value was invalid.<br />

❖ The DDname you specifies does not appear in the COMPAKTOR JCL.<br />

❖ The device type allocated to the DDname is not TAPE or DISK.<br />

❖ VOL= was also coded (you cannot use both).<br />

Action: Correct the error and rerun.<br />

CPK406E INVALID OR INCONSISTENT USE OF KEYWORD -- operand<br />

Reason: The operand “operand” is not valid for the form of the DSNAME statement you used, or<br />

conflicts with a mutually exclusive keyword that was also specified.<br />

Action: Correct the error and rerun.<br />

CPK407E<br />

Reason:<br />

Action:<br />

LAST ’SEQ’ COMMAND SPECIFIED A NULL SET, OR THE ’ENDSEQ’ COMMAND IS<br />

NOT PRECEDED BY A ’SEQ’ COMMAND.<br />

No SELECT control statements were found between a SEQ and an ENDSEQ<br />

statement, or an ENDSEQ control statement is misplaced.<br />

Correct error and rerun.<br />

CPK408E LAST READ CONTROL STATEMENT IS OUT-OF-SEQUENCE.<br />

Reason: A major statement is preceded by one or more minor statements, or a SELECT DSG=<br />

statement precedes a SELECT DSN/SEQ/ENDSEQ statement group.<br />

Action: Correct the error and rerun.<br />